Table 1 Installation (continued)
Field Installation
(continued)
Level the Device
Use the bubble level underneath the ATMOS 41W to level the weather station.
The weather station angle can be adjusted by (1) loosening the leveling screw
attached to the bottom with the 8-mm wrench (included), (2) moving the weather
station side to side as needed to level, and then retightening the screw.
The ATMOS 41W must be within approximately ±2° of dead level to accurately
measure rainfall and solar radiation.
Loosen the
level screw
Slide the
ATMOS 41W
side-to-side
Bubble
level
1
2
Reverify Communication Signal and Cellular Signal
Use ZENTRA Utility Mobile to review instantaneous measurements and verify
the sensor is working as expected.
Press
Test in ZENTRA Utility Mobile to check the quality of the cellular signal
before finalizing installation.
The ATMOS 41W is now installed and active. Data should be available after the
first upload.