background image

3. Configure Settings

Configure sensor settings using 
ZENTRA Utility or ZENTRA 
Utility Mobile. Review sensor 
instantaneous measurements to 
verify the installed sensors are 
working.

1. Fasten Logger to  

Mounting Post

Use included zip ties to attach the 
ZL6 to a mounting post. 

Ensure the logger is installed in 
an upright position to reduce the 
possibility of water entering the 
ZL6 enclosure.

Installation

ZL6 BASIC QUICK START

Configuration

Set the logger’s real-time clock and test sensor function prior to and 

during field installation.

Using a Computer

Use the ZENTRA Utility Installer link on the ZL6 webpage 

(

metergroup.com/zl6-support

) to download ZENTRA Utility.

Connect the micro-USB cable to computer and logger. 

Open the ZENTRA Utility application, select the appropriate COM 

port, and select 

Connect

.

Using a Smartphone or Tablet

Open the mobile app store and search for ZENTRA Utility Mobile or 

scan the QR code to open the METER ZENTRA Apps website.

On the ZL6, push the TEST button to activate the Bluetooth module.

On the smartphone, select the device in 

Devices Found

.

 Preparation

Inspect and verify ZL6 Basic components are intact. Installation will 

require a mounting post.

Install the enclosed batteries and press the TEST button. The status 

lights will eventually settle to a short, single green blink every 5 s, 

signaling it is ready for use.

Read the full 

ZL6 User Manual

 at 

metergroup.com/zl6-support

. All 

products have a 30-day satisfaction guarantee.

NOTE:  The ZL6 case is water resistant, not waterproof. See the ZL6 User Manual for tips 
to use the logger in extremely wet environments.

Data Access with ZENTRA Cloud

ZENTRA Cloud is a cloud-based web application to download, view, 

and share ZL6 data. Data can be uploaded using either ZENTRA 

Utility Mobile on a Bluetooth

®

-enabled device or ZENTRA Utility 

after doing a download via USB to a computer.

Visit 

zentracloud.com

 to access all ZL6 data online. 

A free trial of 

ZENTRA Cloud is available for new users.

2. Install Sensors

Install sensors according to the 
user manuals. Plug the sensor 
connectors into the ZL6 sensor 
ports. Secure cables to mounting 
post with some cable slack.

18383-00

4.10.2020

For answers to common questions, visit

  

metergroup.com/environment/faqs/zl6

Port 1

Port 2

Port 3

Port 4 

Port 5

Port 6

TEST

OK

ERROR 

(-)

(-)

(-)

(-)

(-)

(+)

(-)

(+)

(+)

(+)

(+)

(+)

ZL6 Basic Clock Sync

The ZL6 Basic requires a time sync to accurately save a time and 

date stamp with each sensor measurement record. This time 

sync happens when the logger connects to ZENTRA Utility or 

ZENTRA Utility Mobile.

The time 

must be reset any time the logger loses power (when 

batteries are removed or replaced).

Reviews: