9
USE
ENGLISH
2A) Power On/Off
If POF=1 (default) press the ON-STAND-BY button for 2 seconds.
If the device is switched on, the display shows the value PS (default “cell temperature”). If the display shows an alarm code, see the
'”Alarms” chapter.
2B) Unlocking the keypad
If POF=1 (default) press the ON-STAND-BY button for 2 seconds.
If the device is switched on, the display shows the value PS (default “cell temperature”). If the display shows an alarm code, see the
'”Alarms” chapter.
2) MAIN FUNCTIONS
2C) Setting the setpoint
- Ensure the keypad is not locked.
- Tap the SET button
- Tap the UP or DOWN button within 15 seconds to set the value between the r1 and r2 limits (default “-40... 50°C)
- Tap the SET button or do not operate for 15 seconds
2D) Manual defrosting
Manual defrosting is active if r5=0 (default)
- Ensure that the keypad is not locked and overcooling is not in progress
- Press the DEFROST button for 2 seconds
If P3=1 (default), defrosting is activated provided the evaporator temperature is below the threshold d2.
2E) Switching cell light on/off
This only applies if u1c...u5c = 5.
To switch the cell light on or off, simply tap the CELL LIGHT button.
2F) Switch on/off working load
This only applies if u1c...u5c = 10 or 11.
Simply tap the CELL LIGHT button.
2G) Muting the buzzer
Simply tap any button.
If u1c...uc5=11 and u4=1 it will also deactivate the alarm output.
Summary of Contents for 4247252
Page 27: ...Huomautuksia ...
Page 28: ......
Page 29: ...MANUAL GASTRONOMISKÅP EVJ SV MANUAL FÖR ANVÄNDNING OCH UNDERHÅLL GASTRONOMISKÅP EVJ ...
Page 55: ...Anmärkningar ...
Page 56: ......
Page 57: ...GASTRONOMY EVJ CABINET MANUAL EN USE AND MAINTENANCE MANUAL GASTRONOMY CABINET EVJ215 ...
Page 83: ......
Page 84: ...BN6LIBV003 ...