24
ENGLISH
ALARMS
Code
Alarm type
Reset
Solutions
Pr1
Cell probe alarm
Automatic
- Check P0
- Check integrity of probe
- Check electrical connection
Pr2
Evaporator probe alarm
Automatic
Pr3
Auxiliary probe alarm
Automatic
rtc
Clock alarm
Manual
Set the date, time and day of the week
AL
Low temperature alarm
Automatic
Check A0, A1 and A2
AH
High temperature alarm
Automatic
Check A4 and A5
id
Door open alarm
Automatic
Check i0 and i1
PF
Power failure alarm
Manual
- Tap any button
- Check electrical connection
COH
High condensation alert
Automatic
Check C6
CSd
High condensation alarm
Manual
- Switch the device off and on again
- Check C7
iA
Multifunctional input alarm
Automatic
Check i5 and i6
iSd
High pressure alarm
Manual
- Switch the device off and on again
- Check i5, i6, i8 and i9
LP
Low pressure alarm
Automatic
Check i5 and i6
C1t
Compressor thermal protection alarm
Automatic
Check i5 and i6
C2t
Compressor 2 thermal protection alarm
Automatic
Check i5 and i6
dFd
Defrost timeout alarm
Manual
- Tap any button
- Check d2, d3 and d11
FUL
SD card space full alarm
Manual
Free up space on SD card or replace it
Sd
SD card not inserted alarm
Manual
Insert SD card or replace it
Summary of Contents for 4247252
Page 27: ...Huomautuksia ...
Page 28: ......
Page 29: ...MANUAL GASTRONOMISKÅP EVJ SV MANUAL FÖR ANVÄNDNING OCH UNDERHÅLL GASTRONOMISKÅP EVJ ...
Page 55: ...Anmärkningar ...
Page 56: ......
Page 57: ...GASTRONOMY EVJ CABINET MANUAL EN USE AND MAINTENANCE MANUAL GASTRONOMY CABINET EVJ215 ...
Page 83: ......
Page 84: ...BN6LIBV003 ...