1.11.2102
7
4.
Adjusting the temperature
Set point setting (desired temperature value)
•
press SET for 1 s, the set value will start flashing;.
•
increase or decrease the value using UP or DOWN.
•
press SET to confi rm the new value.
The setpoint has been set at the factory to +4°C (refrigerator) and -18°C (freezer). Don’t
change the parameters if not necessary!
Manual defrost
The defrosting of the appliance is automatic but manual defrosting can be carried out when
needed as follows:
•
Press DOWN for more than 3 s (activated only if the temperature conditions are right).
•
Defrosting starts. After the defrosting the appliance goes back to normal function.
Signal lights (LEDs)
Each button is equipped with a signal light. When lit the lights indicates:
•
UP / ON-OFF
compressor active
•
DOWN / MANUAL DEFROST
defrost active
•
SET
alarm
A flashing signal light indicates that a delay is active and that the function starts in a mo
-
ment.
UP / ON-OFF
DOWN / MANUAL DEFROST
SET