18
Part Number 4532287 Rev 5 12/15
Installation
Section 2
APPLICATION EXAMPLE 2
• The equipment is built into a small, enclosed
compartment of a buffet counter with an open base.
• Illustration, bottom, shows an example of mounting
the generator horizontally with the cooling fan on
the bottom. Risers or brackets are used to secure the
generator (below, item 13, not provided).
• This application requires a custom made, short fresh
air intake path (below, item 10, not provided). The
fresh air intake vent can be installed on the base of the
compartment.
,
Caution
When a short, direct path to the air intake fan is
used, ensure to provide a finger guard on the fan.
• Air intake filter and holder shown are not provided.
Illustration, item 11: Plastic holder, part number
72261030. This holder can be mounted directly onto the
bottom of the cabinet. Item 12, reusable and dishwasher
safe air filter, part number 71000003.
• See xx for the descriptions of items
1
to
7
in
illustration.
3
1
2
4
5
7
6
Application Example 2: Equipment Built Into A Counter With An Open Base.
Indicates the direction of airflow for fresh air.
Indicates the direction of airflow for exhaust air.
12
13
1
11
10
1
Application Example 2: Side View of Induction Generator and Custom Made Air Intake Path.
Indicates the direction of airflow for fresh air.