background image

8.4.2016

METOS Ardox IEC

14

 |

Error Code

Name

Cause

Corrective action

E1<->01

Hardware over current

Unsuitable pan material

Use suitable pan material

Wrong or defective coil

Check  the coil  / Call Service

E1<->02

No inductor current

Inductor  connection failure

Call Service  Engineer.

E1<->03

IGBT temperature too high Air routes blocked.

Fan clogged, temperature sen- 

sor of IGBTdefective

Clear air routes.

Clean fan, check  fan rotation

E1<->04

Cooking zone temperature 

too high or too low

Pan empty

Remove pan, check  pan base. Switch  off, allow 

zone to cool and try again.

Temperature sensor faulty

The sensor must be replaced

Power board faulty

Replace the generator

E1<->05

Control unit failure

Control unit defective or wiring 

defective

Check  or replace operating unit, check  wiring har- 

ness to unit

Digital control has faulty ID

Switch  the generator off, adjust  the DIP switches 

correctly

Control unit faulty

Replace the control unit

E1<->06

Internal temperature too 

high

Air routes blocked

Fan clogged, temperature sen- 

sor defect, close  exterior  heat 

sources

Clear air routes

Clean fan

E1<->07

Coil temperature

Coil temperature too high

Remove pan, switch off and wait a couple  of min- 

utes until cooking  field has cooled  down

Temperature sensor faulty

The sensor must be replaced

E1<->08

Mains phase failure

Breakdown of mains  phase or 

mains  quality insufficient

Check  mains  supply

E1<->10

Communication error

Failure in LIN or CAN-Bus No 

connection between keyboard 

and generator

Disconnect from mains  and check  connection

1 E1<->11

Initialisation error

Needless control unit con- 

nected

Connect control unit to the correct control plug

Digital control has faulty ID

Switch  generator off, adjust  the control

Failure while initialising of the 

hardware

Just wait, the device  will be reset approx.  every 

30 sec

E1<->13

Mains connection error

Mains voltage  too high or too 

low

Check  mains  connection

E1<->14

Mains adaptor error

Mains voltage  is too high or 

too low

Check  mains  connection

E1<->15

Empty pan protection

Mains error

Switch  off the main fuse, wait a few seconds and 

switch on

Empty pan

Remove pan, switch off and wait for a couple  of 

minutes until the cooking  field cooled  down

Defective temperature sensor 

coil

The sensor must be replaced

Summary of Contents for IEC4

Page 1: ...Installation and Operation manual 8 4 2016 S N 155549 18 Rev 1 0 INDUCTION RANGES METOS ARDOX IEC TYPE IEC4 IEC6 4210070 4210073...

Page 2: ...5 3 3 1 Operating switches and indicator lights 5 4 Operation instructions 6 4 1 Before using the appliance 6 4 1 1 Selecting cookware for ceramic hobs with infrared heating 6 4 1 2 Selecting cookware...

Page 3: ...above may put the safety of the appliance in danger The manufacturer does not take responsibility for any damages in case the operation in structions and warnings contained in this manual are neglecte...

Page 4: ...hob surface Metallic objects such as kitchen utensils cutlery etc shall not be placed on hob sur face within induc tion heating zones as they could get hot Take care when operating induction heating s...

Page 5: ...on heating source Electromagnetic field influences only the bottom of cookware Energy transfer stops immediately if cook ware is taken away from hob surface and starts again when cookware has been pla...

Page 6: ...magnet The magnet must stick to the bottom of cookware The cooking zone with pots diameter of over 120mm will be activated put will not give the maximum power 5kW Maximum power will reached with pot...

Page 7: ...ll not Operate 120mm pan Ideal but positioned incorrectly Only half the pan contents will cook as outer circle markings have been compromised Zone will Operate however 180mm pan Ideal for cooking Alth...

Page 8: ...amatically reduced during cooking It may not even be detected Note This is also liable to happen if pans are damaged e g large dents Pot base is bowed inward and is NOT FLAT The unit efficiency will b...

Page 9: ...e range should be set to 0 position This should be done to prevent unexpected start up of the range when electricity supply is restored 4 2 2 Cooking hints 1 Before use ensure hob surface is clean dry...

Page 10: ...he ceramic hob surface they can be also removed with a scraper For cleaning always prefer chemical cleaning methods rather than mechanical rubbing Use a slightly alkaline detergent pH 8 10 diluted in...

Page 11: ...lifting must be done from the bottom frame using suitable spacers of wood In order to avoid damages it is not allowed to use ceramic hob surface as a workbench during installation 5 4 Positioning the...

Page 12: ...al The terminal is on the right side inside the enclosure To assemble appliance carry out operations described above in opposite order Before close the ceramic hob check that no wires inside the range...

Page 13: ...ty Check replace knob switch Empty cooking zone starts operating Pan detection faulty Replace generator call service Small metal objects are heated Pan detection faulty Replace generator call service...

Page 14: ...fect close exterior heat sources Clear air routes Clean fan E1 07 Coil temperature Coil temperature too high Remove pan switch off and wait a couple of min utes until cooking field has cooled down Tem...

Page 15: ...N INSTALLATION INSTRUCTIONS MUST ALSO BE FOLLOWED ARDOX IEC 1 A B C D E F 8 7 6 5 4 3 2 1 1 2 3 4 A B C D E F Position Quantity Pg Page Date Drawn Name Standard Name Filename Changes State Date Checke...

Page 16: ...E F Position Quantity Pg Page Date Drawn Name Standard Name Filename Changes State Date Checked Surface Scale Code S Uus logo III jpg U I n ducti o n range Ardox4I T00390A3 d wg 1 10 Installation draw...

Page 17: ...071 78 38900 060 Out1 Out2 ln Digital I O LIN Service PwrMgmt gn rt Control D Lamps Poti PwrMgmt gn rt Control C Lamps Poti L1 L2 L3 Connect Electric Power PE 9 W 9 F 9 W 9 F Channel C Channel D viol...

Page 18: ...C4H ARDOX IEC4 P ja ohjausvirtapiirin kytkent kaavio Main and control circuit diagram 3 N PE AC 400V 50 60Hz 2 N PE AC 400V 50 60Hz L1 S2 2 S2 S1 P1 P2 4 PILOT 15VA T1 F3 0 25A F2 0 25A F1 0 25A E2 2...

Page 19: ...78 38900 060 violet green H3 5 28V Zone A Cooking Cooking Zone B S1 S2 Cooking Zone 1 Cooking Zone 2 S5 R1 2000W 2000W R2 S2 H2 11 P5 P6 6 5 12 32 1 2 4 L3 S3 78 98100 100 3 N PE AC 400V 50 60Hz Te m...

Page 20: ...ARDOX IEC6 Cooking Cooking Cooking Cooking Ardox IE2 PwrMgmt gn rt Control B Lamps Poti Poti Lamps Control A rt gn PwrMgmt 9 W 9 F Channel A 9 W 9 F Channel B zone B H5 5 28V 78 94020 002 connector L...

Page 21: ...2000W R2 S2 2 S1 S1 P1 P2 4 PILOT 120 S3 S4 Ardox C4 Zone 3 Cooking Cooking Zone 4 Cooking Zone 1 Cooking Zone 2 Cooking Zone 3 Cooking Zone 4 Cooking Cooking S6 S5 S2 S1 Ardox IE2 Cooking Cooking Zo...

Page 22: ...ng zone 4pcs induction Ardox IEC 6 4x5000W 270x270 mm Power regulation Ardox IEC 4 6 Stepless energy regulator indicator lamp for each zone Material Ardox IEC 4 6 Ceramic cooking hob All other surface...

Page 23: ......

Page 24: ......

Reviews: