8.4.2016
METOS Ardox IEC
14
|
Error Code
Name
Cause
Corrective action
E1<->01
Hardware over current
Unsuitable pan material
Use suitable pan material
Wrong or defective coil
Check the coil / Call Service
E1<->02
No inductor current
Inductor connection failure
Call Service Engineer.
E1<->03
IGBT temperature too high Air routes blocked.
Fan clogged, temperature sen-
sor of IGBTdefective
Clear air routes.
Clean fan, check fan rotation
E1<->04
Cooking zone temperature
too high or too low
Pan empty
Remove pan, check pan base. Switch off, allow
zone to cool and try again.
Temperature sensor faulty
The sensor must be replaced
Power board faulty
Replace the generator
E1<->05
Control unit failure
Control unit defective or wiring
defective
Check or replace operating unit, check wiring har-
ness to unit
Digital control has faulty ID
Switch the generator off, adjust the DIP switches
correctly
Control unit faulty
Replace the control unit
E1<->06
Internal temperature too
high
Air routes blocked
Fan clogged, temperature sen-
sor defect, close exterior heat
sources
Clear air routes
Clean fan
E1<->07
Coil temperature
Coil temperature too high
Remove pan, switch off and wait a couple of min-
utes until cooking field has cooled down
Temperature sensor faulty
The sensor must be replaced
E1<->08
Mains phase failure
Breakdown of mains phase or
mains quality insufficient
Check mains supply
E1<->10
Communication error
Failure in LIN or CAN-Bus No
connection between keyboard
and generator
Disconnect from mains and check connection
1 E1<->11
Initialisation error
Needless control unit con-
nected
Connect control unit to the correct control plug
Digital control has faulty ID
Switch generator off, adjust the control
Failure while initialising of the
hardware
Just wait, the device will be reset approx. every
30 sec
E1<->13
Mains connection error
Mains voltage too high or too
low
Check mains connection
E1<->14
Mains adaptor error
Mains voltage is too high or
too low
Check mains connection
E1<->15
Empty pan protection
Mains error
Switch off the main fuse, wait a few seconds and
switch on
Empty pan
Remove pan, switch off and wait for a couple of
minutes until the cooking field cooled down
Defective temperature sensor
coil
The sensor must be replaced