4
Installation Instructions
The mixer should be plugged into a switched socket which isolates all poles and has a
minimum contact clearance of 3mm and located close to the mixer for use in an emergency and to
facilitate servicing.
The machine must be incorporated into a potential equalization system.
The leakage current for this appliance is no greater than 1 mA/KW.
If the electrical supply cable to the machine becomes damaged, it must be replaced by a
specification or higher and suitable for the Mixer’s motor load.
The ground wire is fixed to the machine and this connection must be kept intact.
CAUTION:
The mixer MUST be grounded.
-
The minimum requirement for all electrical equipment is correct operation between air
temperature of +5
℃
and +40
℃
.
-
Electrical equipment is capable of operating correctly when the relative humidity does not exceeding
95% at a maximum temperature of +40
℃
.
-
Electrical equipment is capable of operating correctly at altitude up to 1000m.
-
Electrical equipment is designed to withstand to protected against the effects of
transportation, and storage temperature within a range of -25
℃
to +55
℃
and for short
periods not exceeding 24h at up to +70
℃
.
Operating Instructions
BEFORE USING THE MIXER
Before using the mixer, ensure that all users are familiar with the correct operation of the
machine. In particular, care should be taken to ensure that the bowl and mixing tools are correctly
fitted and that the bowl guard is in position prior to starting the machine.
SAFETY AT WORK
-
NEVER place your hand or any kitchen utensil in the bowl whilst the mixer is in operation.
-
Keep hands, hair and clothing away from moving parts.
-
Isolate the machine from the electrical supply by removing the plug from the socket
before cleaning, servicing or adjusting any parts or attachments.
-
Do not use the machine with any cover or guard removed.
-
Certain operator notice advising about the safe use of this mixer is attached to
the
machine.
OFFICE, SHOPS AND RAILWAY PREMISES ACT, 1963
The above Act requires that this machine and attachments shall be operated only by a
properly instructed person or by an employee who is under the supervision of a properly instructed
person. The instruction shall include indication of the possible dangers arising and the precautions
to be observed. The Act also requires that no person under the age of 18 shall clean a machine if
this exposes him to risk of injury from a moving part of that machine or any adjacent machine.