Electric heated Fry-Tops (600) 11/31
the symbol
(unipotential system).
Important information specifically relating to
appliances in the DROP-IN series
– The appliance must be installed in strict
compliance with the directions given in the
attached drawings.
– Appliances should only be installed on units
made of metal (and not wood and/or other
flammable materials).
– Take particular care with the power lead: the
channelways must be perfectly smooth with no
sharp corners and/or edges. The lead must not, at
any point, be subjected to temperatures of more
than 50
°
C above normal room temperature.
START
-
UP
Function check electrical system
– Start-up the appliance following the instructions
given; check function regularity and make sure
that the controls and heating elements are in good
working order, testing them with the various
function positions.
– Appliances are provided with a safety thermostat
which cuts off power supply to heating elements
if regulation thermostat is faulty.
Nominal heat input check
– After installation and at each maintenance
intervention check the heat input of the
appliance.
– The nominal heat input is stated in the
“Technical data” table.
– The appliance operates at the nominal heat
input when the electrical power is the one stated
in Table T1.
ATTENTION
If the power supply value is not
within the limits indicated in Table T1, interrupt
the operation of the appliance and contact the
electricity delivery body.
ANALYSIS
OF
SEVERAL
FAILURES
Cooking plate does not heat up
– Check fuse valves
– Main switch off
– Insufficient power or wrong electrical connection
– Regulation thermostat faulty
– Wrong connection or elements faulty
– Safety thermostat activated or faulty
Diffcult or lacking temperature adjustment
– Insufficient power or wrong electrical connection
– Regulation thermostat faulty
– Wrong connection or elements faulty
REPLACEMENT
OF
PARTS
SUBJECT
TO
CHANGE
IMPORTANT
Before carrying out repairs, unplug
appliance from mains disconnecting the main
switch.
Sealed components must not be
tampered with.
To reach electrical components, i.e. controls and
INSTALLATION INSTRUCTIONS
WARNINGS
Installation, adjustments and maintenance of the
appliances must be done by authorized installers,
in accordance with the safety standards in force.
The manufacturer declines any responsibility
if such obligation is not observed.
INSTALLATION
Positioning
– The overall/connection dimensions and the
technical data are stated in the pages in the
appendix.
– Install the appliances only in sufficiently aired
rooms.
– Position appliances at least 5 cm from the nearby
walls.
– The appliances are not suitable for built-in
installation.
Assembly
– Remove the film which protects the external
panels. Any glue remaining on these is to be
removed with a suitable solvent.
– Assemble the spacer (if foreseen) by following
the instructions enclosed with the spacer itself.
In line union of the appliances
– Put the appliances next to eachother and level
them at the same height.
– Unite the appliances using the special union
joint-coverings supplied upon request.
Electrical connections
– Appliances are designed to operate at the voltage
indicated on the rating plate.
– Each appliance must be connected to an
independent mains supply of suitable capacity
(total power indicated in “Technical data” table)
with supplied flexible cable (features of which
are indicated in table
T1
).
– Make sure that the cables lenght allows for the
live wires to disconnect from terminal block
before the yellow/green ground wire, in case of
simultaneous pull.
– Automatic cutout omnipolar switches of suitable
capacity (with contacts opening to at least 3
mm) and highly sensitive automatic differential
protective devices must be fitted. These must
ensure that there is no direct or indirect contact
between live components and fault currents
and the ground, in accordance with current
regulations (maximum admissible leakage
current 1 mA/kW).
Earth and unipotential connections
– Appliances must be earthed on terminals marked
with the symbol .
– Connect the metallic structure of every electrical
appliance installed to the terminals, marked by