2.11.2005
Rev. 1.5
Troubleshooting
50
7.
Troubleshooting
MALFUNCTION
POSSIBLE CAUSE
WHAT TO DO
The kettle cannot be
switched on
The mains switch is in the OFF position
Turn the mains switch fitted on the rear part of
the control pillar right side to the ON position
The emergency/stop button is pushed
Release the emergency-stop switch by turning it
clockwise
The fuses in the main fuse box areblown/trig-
gered
Change/excite the fuses
The delivery of electric energy is interrupted
Check if the delivery of electric energy is inter-
rupted elsewhere and wait for it to return
The kettle does not heat
The timer function is activated if the kettle is
equipped with a timer
Switch off the timer function according to in-
structions
The EasyRun function is activated if the kettle is
equipped with the option
Switch off the EasyRun function according to
instructions
The emergency/stop button is pushed
Release the emergency-stop switch by turning it
clockwise
The ON/OFF switch is not in the ON position
Push the switch to the ON position
On a kettle fitted with automatic cooling: The
draining of the cooling water is still unfinished
Wait until time on the display next to the cooling
button runs out
The fuses in the main fuse box are blown/trig-
gered
Change/excite the fuses
The kettle is not returned to an upright position
after tilting, the temperature display shows a
'PoS' signal
Press the tilting reverse button until the kettle is
totally horizontal and the temperature display
shows an 'On' signal
Electric kettle: Not enough water in the steam-
generator, the two red error lights on the control
panel are illuminated
Check that the shut-off valve of the water supply
line is in the OPEN position
Steam kettle: The shut-off valve of the steam in-
put is closed
Open the valve
Other technical fault
Contact qualified technical personnel
Heating of the kettle is
slow
Electric kettle: Too much water in the steamgen-
erator
Check the water level of the steam generator ac-
cording to the instructions by opening the emp-
tying valve.
Steam kettle: Condensate water gathered in the-
steam jacket has not been emptied
Remove the condensate by opening the empty-
ing valve which is in the steam jacket
The steam jacket of a kettle equipped with a
manual cooling system (C1) is full of cooling
water which has not been emptied
Remove the chilling water by opening the emp-
tying valve (electric) or the emptying valve for
condensate (steam)
There is air in the steam jacket which does flow
out because the automatic vacuum valve does
not function
If the air does not exit through the automatic
vacuum valve, contact qualified technical per-
sonnel
One of the fuses in the main fuse box is blown/
triggered
Change/excite the fuse
The forced 1/2-power control of the building is
on
Normal operation
Other technical fault
Contact qualified technical personnel
Summary of Contents for PROVENO S 100
Page 2: ......
Page 4: ...2 11 2005 Rev 1 5...
Page 7: ...2 11 2005 Rev...
Page 8: ...2 11 2005 Rev...
Page 62: ...Connection diagram S00123 B3...
Page 63: ...Installation drawing L00115 B3...
Page 64: ...Text part ChillPlus L00114 A4...
Page 65: ...Steam supply recommendations 000030 A4...
Page 68: ......