Model
Width
(A)
Overall
Depth (B)*
Unit
Depth (C)
Height
(D)
Chamber
Width (E)
Footprint
Width (F)
Footprint
Depth (G)
TM-5 and
TM-5H
290
mm
(11-7/16″)
523
mm
(20-5/8″)
419
mm
(16-1/2″)
387
mm
(15-1/4″)
186
mm
(7-3/8″)
260
mm
(10-1/4″)
336
mm
(13-1/4″)
TM-10 and
TM-10H
368
mm
(14-1/2″)
520
mm
(20-1/2″)
419
mm
(16-1/2″)
387
mm
(15-1/4″)
264
mm
(10-3/8″)
338
mm
(13-3/8″)
336
mm
(13-1/4″)
Model
Voltage
Hertz
Watts
Amps
Plug Configuration
Shipping Weight
TM-5
220–240 (CE)
50/60
1340–1595
6.1–6.6
CEE 7/7 Schuko, BS-1363, or AS 3112
16 kg (36 lbs.)
TM-5H
100
50/60
1340
13.4
NEMA 5-15
16 kg (36 lbs.)
120
50/60
1340
11.2
NEMA 5-15
16 kg (36 lbs.)
220–240 (CE)
50/60
1340–1595
6.1–6.6
CEE 7/7 Schuko, BS-1363, or AS 3112
16 kg (36 lbs.)
TM-10
220–240 (CE)
50/60
1940–2300
8.8–9.6
CEE 7/7 Schuko, BS-1363, or AS 3112
19 kg (41 lbs.)
TM-10H
120
50/60
1790
14.9
NEMA 5-15
19 kg (41 lbs.)
220–240 (CE)
50/60
1940–2300
8.8–9.6
CEE 7/7 Schuko, BS-1363, or AS 3112
19 kg (41 lbs.)
SPECIFICATIONS
For
m
No. TMCEM-0212
5
Plug Configurations
Units are supplied fro
m
the factory
w
ith an electrical cord and
plug. Plugs are supplied according to the application.
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage, size,
and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: The specification label is located on the side of the unit.
See label for serial number and verification of unit
electrical information.
WARN
I
NG
Plug Configurations
NOTE: Receptacle not supplied by Hatco.
CEE
7/7
Schuko
AS
3112
BS-1363
NEMA
5-15P
B
C
G
Front
Vie
w
Side
Vie
w
A
E
D
F
Di
m
ensions
Electrical Rating Chart
Dimensions
* Add 195
mm
(7-3/4″) to Overall Depth (B) for units equipped
w
ith a rear discharge tray.