Page 10
Door Access Terminal Combo Technical Manual
User interface connection
CONTROL MODULE
Connect the connection cable to the terminal marked
“
READER
”.
USER INTERFACE
Connect the connection cable to the terminal marked
“
READER IN
”.
Electronic door lock connection
Set the relay output jumpers on the device or on the relay module according your electronic door
lock.
Connect the electronic door lock to the terminals marked “
RELE
” on the control module.
WARNING
Mind the power polarity if one of the options with DC output is selected – see corresponding
schematics. Wrong polarity could result in irreparable damage to the device.
WARNING
Mind the electronic door lock power consumption. 12 V
DC door lock with max
0.5 A
current consumption can be
connected directly to the device. Use additional relay
module for electronic door locks with higher current
consumption.