Page 20
Tripod Turnstile Technical Manual
Maintenance
The maintenance service should perform a check on the device:
At least once a year.
When it has not been in use for a long time.
When functional errors appear.
The device should be protected from mechanical damages, such as bending barriers and similar,
which usually result from improper use like jumping over the barrier or climbing over the bars. Such
abuse can be detected by proximity sensors and will be signalized by a beep sound, if enabled in
device parameters.
Cleaning
The device housing should be cleaned using only detergents, suitable for rust resistant metals. The
resin cover should be cleaned using soft cloth and dedicated cleaners for plastic surfaces e.g. car
dashboard cleaning agents. Do not use any aggressive or abrasive agents or solvents as they might
cause permanent damage to the device surface.
Technical data
Operating voltage
24V DC regulated; (22 – 30V DC tolerated)
Current consumption
2 A
Fuse
Fast Fuse 3.15 A
Operating temperature range
0 to +50 °C
Passage corridor width
50 cm
Barrier height
78.5 cm
Passage frequency
10-12 persons / min
Audio signal
integrated piezoelectric beeper
Visual signalization
LED semaphores
Network type
Metra NET Network
Barrier type
Motorized, absolute position magnetic sensor
Dimensions in mm (w/h/l)
740/980/1220
Appendix
1
Physical dimensions
2
Typical Installation