MD 9016 Digital Multimeter Series
Specifications
16
Capacitance
RANGE Accuracy
60.00nF, 600.0nF
2.0%+5d
6.000
F, 60.00
F, 600.0
F 1.5%+5d
3000
F 2.0%+5d
Accuracies with film capacitor or better
Diode Tester
RANGE Accuracy
1.000V
1.0% + 3d
Test Current: 0.56mA typically
Open Circuit Voltage: < 1.8VDC typically
DC Current
RANGE Accuracy
Burden
Voltage
600.0
A 0.5%+5d
6000
A
0.5%+3d
0.10 mV/uA
60.00mA
0.5%+5d
600.0mA
0.5%+3d
1.7 mV/mA
6.000A 1.2%+6d
8.00A
1)
1.8%+6d
0.03V/A
1)
8A continuous, >8A to 15A for 30 sec. max with 5 minutes cool down interval
AC Current
RANGE Accuracy
Burden
Voltage
50H
Z
~
400H
Z
600.0
A, 6000
A 0.10
mV/uA
60.00mA, 600.0mA
1.0%+3d
1.7 mV/mA
6.000A 1.2%+6d
8.00A
1)
1.8%+6d
0.03V/A
1)
8A continuous, >8A to 15A for 30 sec. max with 5 minutes cool down interval
Temperature
RANGE Accuracy
-50
o
C ~ 1000
o
C
0.3% + 3d
-58
o
F ~ 1832
o
F
0.3% + 6d
K type thermocouple range & accuracy not included
Logic Level Hz (mV Function)
RANGE
Sensitivity
(square wave)
5.00 Hz ~ 500.0 kHz
3 Vpeak
5.00 Hz ~ 1.000 MHz
5 Vpeak