6.1 Creating test reports
When
Receive Measurements
in
Receive Results
window is selected, the LANlink
Result Screen appears.
The following actions can now be taken:
6.1.1 Defining original location names
After opening a file the memory structure with stored data is displayed on the left side of
the screen, named Installation Structure Editor. The results that are received from the
instrument are defined with numbers only.
After clicking on an object, floor or cable number it can be changed to any alphanumeric
name. The new name is stored by pressing Enter.
6.1.2 Adding operator/test site header and comments
When selecting the Operator/Test site menu the operator can create his own Test
Report Header and Footer. BMP logo can be added.
When selecting Comments menu any text can be added to the Test Report Header.
6.1.3 Selecting complexity of Test Reports
If large installations are tested, the Test Reports with complete measuring results
becomes very complex and difficult to examine.
Therefore the operator can choose between three detail levels (and also print them out):
Full Detail Report:
Full Detail Report provides the most complete information about the performed
measurements (including Pass/Fail decisitions for performed measurements, overall
headroom, results or margins for individual pairs).
Medium Detail Report:
In the Medium Detail Report Pass/Fail decisition for performed measurements and the
overall headroom for individual cables are displayed.
Low Detail Report:
In Low Detail Report result column the overall Pass/Fail decisition and headroom for
individual cables are displayed. Low Detail Report enables you to make a clear and
simple Test Report providing essential information.
6.1.4 Viewing Plots
NEXT, ELFEXT, PSNEXT, PSELFEXT, Attenuation, Return Loss, ACR, PSACR, TDR
and TDnext plots that are selected in
Receive Results
window, can be viewed and
modified for printing in this window. On the right side pairs, adjacent pairs and limits can
be switched on or off. The plots contain additional information about Test Standard and
Cable Type, date & time of measurement etc.
From this screen the plots can be saved or printed out.