4.2.2 Connection to a 3-phase outlet
Figure 4-2: Connection of the Application Trainer to 3-phase outlet.
After connecting the MI 3399 to the wall outlet check if lights L1, L2 and L3 are ON.
Turn the Application Trainer ON by switching the circuit breaker on the bottom of the
error switch panel (4 in Figure 4-4: Parts of the Application Trainer explained.). When
the switch is turned ON, lights L1, L2 and L3 should light up.
If lights L1, L2 and L3 do not light up, check chapter 4.2.3 Error handling for further
information.
4.2.3 Error handling
Note:
The equipment contains a special input protection circuit.
This circuit checks if any voltage is present between N and PE conductors to ensure
that correct pins on the plug are connected to the correct conductors (L to L, N to N,
PE to PE). The circuit decides this based on the measured voltage between N and PE
points:
If the measured voltage is
below 25V
1
, the
MI 3399 will start
. Lights L1, L2 and
L3 will turn on.
If the measured voltage is
above 25V
, the
MI 3399 will not start
. Lights L1, L2
and L3 will not show. In this case, the N and L positions must be changed.
o
In case a
1-phase outlet
is used, simply
rotate the plug
.
o
In case a
3-phase outlet
is used, check if the socket has the conductors
correctly connected. If not fix the wall outlet.
Attention! Please ensure minimum of 20 s between unplugging the
Application Trainer and plugging it in again for safety reasons.
1
Note that line impedance does not have any effect powering ON/OFF the MI 3399. It does have an
effect on the line impedance (Z
Line
) measurement conducted in the Application Trainer.
Summary of Contents for MI 3399
Page 27: ...Electrical Installation Safety Trainer AD 1 MI 3399 27...
Page 46: ...Electrical Installation Safety Trainer AD 1 MI 3399 46 3 Exit settings...
Page 74: ...Electrical Installation Safety Trainer AD 1 MI 3399 74...
Page 197: ...Power and Voltage Quality Trainer AD 2 MI 3399 197 Figure 4 89 Transient Chart view...
Page 204: ...PAT Appliances Machines Safety Trainer AD 3 MI 3399 204...
Page 249: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 249...
Page 250: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 250 AD 4 MI 3399 PV Photovoltaic Systems Trainer...