5.2 Portable appliance of class 1
– Flatiron
Simulates
Error value
Error off
Error on
Simulation between contacts
Measurement
taken
Error off
Error on
Error 1
Loose contact of PE conductor Error value
0,02 Ω
0,84 Ω
Earthed metal part (2) and PE
pin on socket (3)
Earth Bond
0,02 Ω
0,84 Ω
Error 2
Insulation fault
Error value
>20 MΩ
106 kΩ
L and PE pins on socket (3)
Insulation 500 V
DC
>20 MΩ
0,106 MΩ
Leakage 230 V,
50/60 Hz
0,00 mA
2,17 mA
Subleakage
0,00 mA
2,17 mA
Error 3
Excessive capacitive current
Error value
/
33 nF
L and PE pins on socket (3)
Insulation 500 V
DC
>20 MΩ
>20 MΩ
Leakage
230V
50/60 Hz
0,00 mA
2,12 mA
Subleakage
0,00 mA
2,12 mA
Error 4
Insulation fault
Error value
>20 MΩ
238 kΩ
Accessible isolated metal part
(1) and L pin on socket (3)
Insulation 500 V
DC
>20 MΩ
0,238 MΩ
Touch
Leakage
230 V
0,00 mA
0,97 mA
Subleakage
0,00 mA
0,97mA
Summary of Contents for MI 3399
Page 27: ...Electrical Installation Safety Trainer AD 1 MI 3399 27...
Page 46: ...Electrical Installation Safety Trainer AD 1 MI 3399 46 3 Exit settings...
Page 74: ...Electrical Installation Safety Trainer AD 1 MI 3399 74...
Page 197: ...Power and Voltage Quality Trainer AD 2 MI 3399 197 Figure 4 89 Transient Chart view...
Page 204: ...PAT Appliances Machines Safety Trainer AD 3 MI 3399 204...
Page 249: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 249...
Page 250: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 250 AD 4 MI 3399 PV Photovoltaic Systems Trainer...