PAT Appliances & Machines Safety Trainer
AD 3
– MI 3399
246
5.8 Electrical machine
Simulates
Error value
Error off
Error on
Simulation between contacts
Measurement
taken
Error off
Error on
Error 1
Loose contact of PE conductor
Error value
0,02 Ω
0,43 Ω
PE input connection (4) and earthed
metal part (2)
Earth Bond
0,02 Ω
0,43 Ω
PE input connection (4) and earthed
metal part (1)
Earth Bond
0,02 Ω
0,02 Ω
Error 2
Insulation fault
Error value
>20 MΩ
1.88 MΩ
L (3) and PE (4) input connections
Insulation 1000 V
DC
>20 MΩ
1.880 MΩ
Withstanding 1000
V AC
0,1 mA
0,6 mA
Error 3
Excessive charge on filter capacitors
Error value
4.7 nF
100
MΩ
100 nF
100
MΩ
L and N on input connection (3)
Discharging time*
cca 0,4 s
cca 9 s
Error 4
Functional fault
Functional
/
interruptions
Functional
Functional
/
interruptions
Table 5-7: Description of simulated faults / relevant tests
* Measured with CE Multitester (resistance of measuring circuit 40
MΩ). Discharging
times for other test instruments can vary, depending on their internal resistance.
Summary of Contents for MI 3399
Page 27: ...Electrical Installation Safety Trainer AD 1 MI 3399 27...
Page 46: ...Electrical Installation Safety Trainer AD 1 MI 3399 46 3 Exit settings...
Page 74: ...Electrical Installation Safety Trainer AD 1 MI 3399 74...
Page 197: ...Power and Voltage Quality Trainer AD 2 MI 3399 197 Figure 4 89 Transient Chart view...
Page 204: ...PAT Appliances Machines Safety Trainer AD 3 MI 3399 204...
Page 249: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 249...
Page 250: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 250 AD 4 MI 3399 PV Photovoltaic Systems Trainer...