Electrical Safety and Quality ApplicationTrainer - Introduction
MI 3399
7
2 Description of MI 3399 Application Trainer set
modules
All modules are fully functional once the Application Trainer MI 3399 is powered ON.
2.1 AD1 MI 3399
– EIS Electrical Installation Safety Trainer
EIS Electrical Installation Safety Trainer sub-modules:
- Low Voltage Electrical Installation Safety Trainer
- TN / TT / IT Earthing Systems Trainer
- Lightning Protection trainer, Surge Protection Trainer
- Special Installations and Locations Safety Trainer
This module comes together with the following equipment:
MI 3152 ST Eurotest XC - Multifunctional Installation Tester
MI 3110
EurotestIM - Special Installation Tester
MI 3242
MicroOhm 2A-Earth Bonding 4-wire
MI 3121H
2,5 kV HV Insulation Analyser
MI 3123
Smartec - Earth/Clamp Tester
MI 2014
Cable Scanner - LAN Cable Tester
MD 9272
Leakage Clamp TRMS with Power & Harmonics
A 1018
Current Clamp - (low range, leakage)
A 1019
Current Clamp
S 2009
Test lead set, 2m, 4pcs
25 pcs
Guide for testing and verification of low voltage installations
25 pcs
Guide for measurements on IT power installation
25 pcs
Chart Verification on Low-voltage electrical installations
Poster
Verification on Low-voltage electrical installations
Poster
Medical Sites
Poster
Fire Brigades
Electrical Safety and Quality Application Trainer Package Set enables performing of
the following tests:
- Continuity of PE conductors
- Earth Bonding 4-wire (with MI 3242)
- Insulation resistance
- HV Insulation Analysing, PI, DAR factors (with MI3121H)
- Line impedance
- Loop impedance
- RCD testing (Contact voltage, trip-out time, trip-out current, Autotest)
- IMD, ELM, RCM leakage and insulation monitors adjustment and test
- Earth resistance (4-wire, 3-wire, 2-wire, two current clamps)
- Specific earth resistance
- Lightning protection loops and legs resistance
- Surge protector test
- Leakage current
- Phase rotation
- AUTOSEQUENCE
®
procedure for TN, TT or IT earthing system.
Summary of Contents for MI 3399
Page 27: ...Electrical Installation Safety Trainer AD 1 MI 3399 27...
Page 46: ...Electrical Installation Safety Trainer AD 1 MI 3399 46 3 Exit settings...
Page 74: ...Electrical Installation Safety Trainer AD 1 MI 3399 74...
Page 197: ...Power and Voltage Quality Trainer AD 2 MI 3399 197 Figure 4 89 Transient Chart view...
Page 204: ...PAT Appliances Machines Safety Trainer AD 3 MI 3399 204...
Page 249: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 249...
Page 250: ...PV Photovoltaic Systems Trainer AD 4 MI 3399 250 AD 4 MI 3399 PV Photovoltaic Systems Trainer...