value for RLcs,DC will be submitted and used for DC current calculations.
Alternative way to calculate and submit RLcs,DC
It is also possible to enter measured DC voltage and current values for the given pipe section or structure to
calculate the actual RLcs,Dc value. Check the "
Or find RLcs,Dc by calculation
" box:
The online calculator takes values for currents and voltages measured both ways and sets RLcs,Dc to the
mean value between the forward and reverse measurements:
𝑅𝐿
𝑐𝑠,𝐷𝐶
= ½ ∙ (
2 𝑚𝑉
2.0 𝐴
+
2.0 𝑚𝑉
2.1 𝐴
) = 0.976 𝑚
Ω
Click
"Calculate"
and the actual
and nominal values for RLcs,DC will be shown to the right.
Click
"Submit"
and the
actual
value for RLcs,DC will be submitted and used for DC current calculations.
Actual value for
RLcs,DC