MetriCorr
Slimline series
–
ICL-C & MasterLink Operation Manual
27 | 54
An overview of the columns in the" Logged data from (UTC)" table above is described in Table 4 below:
Table 4. Logged data from (UTC): Line Current Sensor
–
parameter description
Parameter
Data (example)
Comment
Date
15-Jan-2021 13:02:39
UTC time stamp of measurement
Pipe
–
Ref terminals
Uac V
0.030
AC voltage measurement in volts
Von,LCS
µV
On-potential in microvolts
Voff,LCS
µV
Off-potential in microvolts
Edc V
0.000
DC voltage measurement in volts
Eoff V
Off DC voltage measurement in volts
LC+ and LC- terminals
Ion,Lcs mA
On-state current in milliamps
Ioff,Lcs mA
Off-state current in milliamps
ILcs mA
10.006
DC current in milliamps (calculated from ULcs,dc and RLcs,Dc)
ULcs,dc mV
10.006
DC voltage measurement in millivolts
ULcs,ac mV
0.009
AC voltage measurement in millivolts
RLcs,Dc m
Ω
1000.00
DC resistance in milliohms (for the given pipe section)
Source
Data delivered by
Masterlink with Mobile
ID: AL02840252
Check which MasterLink sent the measurement
Delete
Deletes the measurement (single line). Cannot be undone!