MetriCorr
Slimline series
–
ICL-C & MasterLink Operation Manual
6 | 54
2.1
MasterLink module connectors & control
The MasterLink module comes with a Status/control button, antenna, and Power supply connectors as
standard. Optional interface connectors are available on-demand.
Figure 2. MasterLink module connectors & control
Table 1. MasterLink - Specifications
MasterLink
–
Specifications
Battery Lifetime
+3 years @ 1h logging intervals and
weekly transmissions
Casing
IP65
Humidity
0-100% RH condensing conditions
Operating conditions
-40 °C to +85 °C
Storage capacity
+200 000 readings
Logging intervals
(Normal mode)
10 min →
∞
, recommended 1 hour
Logging interval
(Campaign mode)
1 sec in pre-defined time intervals
A:
Antenna connection
B:
Status/control button & LED indicator
C:
Power supply connector
(with protective cap)