MetriCorr
Slimline series
–
ICL-C & MasterLink Operation Manual
49 | 54
7.4.2
Example: 24h interval measurement campaign
This example illustrates a 24h measurement campaign, where the daily time is set to 17:00.
7.5
App & Data for satellite connected MasterLinks
As with any other MasterLink-dataloggers from Metricorr, satellite connected MasterLinks can be
accessed on location using the Metricorr App.
The measurements transferred via satellite will provide daily measurements for monitoring to
allow for immediate action, if for example the corrosion rate has accelerated. Hourly
measurements can then be collected for example once a year using the Metricorr app to get a
more precise picture that will reveal possible interference with trains, AC power lines, etc.
498.7
498.72
498.74
498.76
498.78
498.8
498.82
498.84
498.86
498.88
498.9
ER probe thickness [
μ
m], 24h interval measurement campaign
Parameter
Value
Comment
Time for first daily
returned measurement,
HH:MM (UTC)
17:00
Measurement campaign is set to start at 17:00 o’clock.
Time between returned
measurements (hours)
24
Interval between measurements transmitted to WEBservice.