5000-count portable digital multimeter, with current input 

15 

1. 

GENERAL INSTRUCTIONS 

 

You have just acquired a portable digital multimeter and we thank you for your confidence. 
 
This instrument complies with the specification of IEC 61010-1 + A1 + A2, 1995, con-
cerning safety requirements for electronic measuring apparatus. To get the best service 
from this instrument, read carefully this user's manual and respect the detailed safety 
precautions. 
The contents of this manual must not be reproduced in  any form whatsoever without our 
consent. 
 

1.1. 

Precautions and safety measures 

 

1.1.1.  Preliminary 

 

-   This device can be used for measurements on category 

ΙΙΙ

 installations, for voltages 

never exceeding 600 V (AC or DC) relative to the earth. 

 
-  Definition of overvoltage categories (cf. publication IEC 664-1) : 
 
 

CAT 

I

 :  The circuits of CAT 

are protected by measures limiting transient 

 

overvoltages to appropriate low level. 

 

   

Example : protected electronic circuits 

 

CAT

 II

 :  The circuits of CAT 

II

 are power supply circuits of appliances or portable  

   

equipment with transient overvoltages of an average level. 

 

   

Example : appliances and portable equipment 

 

CAT 

III

 : The circuits of CAT 

III

 are power supply circuits of power equipment with  

  

important transient overvoltages.  

 

   

Example : fixed installation or industrial equipment 

 

CAT 

IV

 : The circuits of CAT 

IV

 may comprise very important transient  

 

   

overvoltages.  

 

   

Example : primary supply level 

 

  When using this multimeter, the user must observe all normal safety rules 

concerning: 

- protection against the dangers of electric current. 
- protection of the multimeter against misuse. 

 

  For your own safety, only use the measuring probes which have been delivered with 

the instrument : they conform to the IEC 61010-1 + A1 + A2, 1995 safety standard. 
Before use, check that they are in good working condition. 

 

1.1.2.  During use 

 

 

Test equipment risk assessment

 :

 Users of this equipment and or their employers 

are reminded that Health and Safety Legislation require them to carry out a valid 
risk assessment of all electrical work so as to identify potential sources of electrical 
danger and risk of electrical injury such as from inadvertent short circuits. Where 
the assessment show that the risk is significant then the use of fused test leads 
constructed in accordance with the HSE guidance note GS38 "Electrical Test 
Equipment for use by Electricians" should be used. 
 

  Never exceed the protection limit values indicated in the specifications for each type 

of measurement. 

Summary of Contents for MX 24B

Page 1: ...IMETER DIGITAL MULTIMETER MULTIMETRO DIGITALE MULTIMETRO DIGITAL Notice de fonctionnement page 1 Chapitre User s manual page 14 Chapter Bedienungsanleitung Seite 28 Kapitel Libretto d istruzioni pagin...

Page 2: ...Multim tre digital portable 5000 points avec entr e courant 5 6 18 17 16 15 14 13 12 11 7 1 2 3 4 19 20 21 22 8 9 10 500mA MX 24B 500mADC...

Page 3: ...nfiguration 19 3 5 Multimeter maintenance 19 3 5 1 Fuse self test 19 3 5 2 Battery self test 20 3 5 3 Replacing the battery or fuses 20 3 5 4 Cleaning 20 3 5 5 Storage 20 4 FUNCTIONAL DESCRIPTION 21 4...

Page 4: ...CAT III The circuits of CAT III are power supply circuits of power equipment with important transient overvoltages Example fixed installation or industrial equipment CAT IV The circuits of CAT IV may...

Page 5: ...replaced with fuses of the same rating and type Any adjustment maintenance or repair work carried out on the multimeter while it is live should be carried out only by appropriately qualified personnel...

Page 6: ...misuse of the equipment or use in association with incompatible equipment 2 Modification of the equipment or any related software without the explicit authorization of the manufacturer 3 Repairs nece...

Page 7: ...ect the autoranging mode RANGE AC DC key store a value MEM key activate the MIN MAX AVG detection mode MIN MAX key select a function derived from the main function or switch on the multimeter again af...

Page 8: ...operated F Note For user safety automatic shutdown is also disabled when a measured magnitude voltage current present at the input exceeds dangerous level indicator displayed 3 4 Special configuratio...

Page 9: ...Use the following procedure 1 Disconnect test leads from any inputs terminals 2 Using a appropriate tool make slide the case bottom of the instrument 3 Replace the battery or fuse respect the value a...

Page 10: ...multimeter again after an automatic shutdown It can also be used to access secondary functions associated with the selector switch positions mode AC DC The flowcharts below define these various funct...

Page 11: ...ond short press returns the multimeter to normal mode The MEM sign appears on the display The MEM mode is avaible on all measurement Long press AUTO MEM Accesses or quits the autostore mode The MEM si...

Page 12: ...1000 V ranges Common mode rejection 500 mV range at 50 and 60 Hz better than 120 dB Serial mode rejection at 50 and 60 Hz better than 60 dB Intermittent signal sounds and OL on the display in case of...

Page 13: ...5 3 Acceptance 20 A overload during 30 s max observing a 5 min break at least between two measurements Specifications applicable from 5 to 100 of the range for a sinusoidal signal in band 40 Hz to 1 k...

Page 14: ...of points 5 000 Range selection automatic or manual Maximum open circuit voltage 4 V 5 2 7 Diode threshold voltage measurement Measurable voltages 0 to 1 999 V Measurement current 1 mA 20 Resolution...

Page 15: ...measurements s Bargraph 20 measurements s 5 2 11 Environment Reference temperature 23 C 5 C Limit range of operation 5 C to 45 C Rated range of use 10 C to 55 C Storage temperature range 20 C to 70 C...

Page 16: ...K thermocouple 1 mV C general purpose and surface type 25 C to 350 C HK0210N Optical tachometer 100 rpm to 60 000 rpm HA1237 Current clamps Range 200 AAC 1 AAC 1 mVAC max cable 20 mm connection socket...

Page 17: ...g des Multimeters 33 3 5 1 Selbsttest der Sicherungen 33 3 5 2 Selbsttest der Batterie 34 3 5 3 Ersetzen der Batterie und der Sicherungen 34 3 5 4 Pflege 34 3 5 5 Lagerung 34 4 FUNKTIONSBESCHREIBUNG 3...

Reviews: