background image

Multimètre digital portable 

LEGENDE / CAPTION / BESCHREIBUNG / LEGENDA / LEYENDA 

Borne d'entrée calibres 11, 12, 13, 14, 15 

11 Mesure de tensions alternatives 

Entrée de référence du multimètre 

12 Mesure de tensions 500 mV 

Borne d'entrée calibres mA 

13 Mesure de tensions continues 

Borne d'entrée calibre 10 A 

14 Mesure de résistance 

Mise sous tension (sélection fonctions secondaires) 

15 Mesure de capacité 

Changement de gamme 

16 Mesure de courant jusqu’à 5 mA 

Mesure en mode relatif 

17 Mesure de courant jusqu’à 50 mA 

Mesure de crêtes 

18 Mesure de courant jusqu’à 500 mA 

Gel de l'affichage 

19 Mesure de courant jusqu’à 10 A 

10  Mise hors tension 

20 Envoi de données vers imprimante 

Input terminal, ranges 11, 12, 13, 14, 15 

11 AC voltage measurement 

Multimeter reference input 

12 500 mV voltage measurement 

Input terminal, ranges mA 

13 DC voltage measurement 

Input terminal range 10 A 

14 Resistance measurement 

Power on (selects secondary functions) 

15 Capacitance measurement 

Range change 

16 Current measurement up to 5 mA 

Relative mode measurement 

17 Current measurement up to 50 mA 

8 Peak 

measurement 

18 Current measurement up to 500 mA 

Display hold 

19 Current measurement up to 10 A 

10  Power off 

20 Data sending to a printer 

Eingangsbuchse für Meßbereiche 11,12,13,14,15 

11 Messung von AC-Spannungen 

COM-Eingangsbuchse 

12 Spannungsmessung bis 500 mV 

Eingangsbuchsen mA 

13 Messung von DC-Spannungen 

Eingangsbuchse  10 A 

14 Widerstandsmessung 

Multimeter Einschalten (+ Zweitfunktionen)

15 Kapazitätsmessung

Bereichsumschaltung 

16 Strommessung bis 5 mA 

Relativ-Messung 

17 Strommessung bis 50 mA 

Spitzenwertmessung 

18 Strommessung bis 500 mA 

Anzeige speichern 

19 Strommessung bis10 A 

10  Multimeter Ausschalten 

20 Sendung von Angaben zum Drucker 

Borne de entrada calibres 11, 12, 13, 14, 15 

11 Medida de tensiones alternativas 

Entrada de referencia del multÍmetro 

12 Medida de tensiones 500 mV 

Borne de entrada calibres  mA 

13 Medida de tensiones continuas 

Borne de entrada  calibre 10 A 

14 Medida de resistencias 

Puesta en servicio (+ funciones segundarias) 

15 Medida de capacidades 

Cambio de calibre 

16 Medida de corrientes hasta 5 mA 

Medidas relativas 

17 Medida de corrientes hasta 50 mA 

Medidas de cresta 

18 Medida de corrientes hasta 500 mA 

Memorizacion de la representacion visual 

19 Medida de corrientes hasta 10 A 

10  Puesta fuera de servicio 

20 Transmisión de los datos hacia una 

impresora 

Boccola d’ingresso portate 11, 12, 13, 14, 15 

11  Misura delle tensioni alternate 

Ingresso di riferimento del multimetro 

12  Misura delle tensioni 500 mV 

Boccola d’ingresso portate mA  

13  Misura delle tensioni continue 

Boccola d’ingresso portata 10 A 

14  Misura di resistenza 

Accensione (scelta funzioni secondarie) 

15  Misura della capacità 

Cambiamento di portata 

16  Misura di corrente fino a 5 mA 

Misura in modalità relativa 

17  Misura di corrente fino a 50 mA 

Misura delle creste 

18  Misura di corrente fino a 500 mA

 

Immobilizzazione della visualizzazione 

19  Misura di corrente fino a 10 A

 

10  Spegnimento 

20  Invio dati verso la stampante

 

Summary of Contents for MX 58HD

Page 1: ...istruzioni Manual de instrucciones ENGLISH page 16 Chapter II Office Jl Radin Inten II No 62 Duren Sawit Jakarta 13440 Indonesia Workshop Jl Pahlawan Revolusi No 22B Jakarta 13430 Indonesia Phone 021...

Page 2: ...Multim tre digital portable 8 9 7 10 11 12 13 5 20 6 19 18 17 16 15 14 1 2 3 4...

Page 3: ...14 Widerstandsmessung 5 Multimeter Einschalten Zweitfunktionen 15 Kapazit tsmessung 6 Bereichsumschaltung 16 Strommessung bis 5 mA 7 Relativ Messung 17 Strommessung bis 50 mA 8 Spitzenwertmessung 18...

Page 4: ...test leads 21 3 2 Switching on the instrument 21 3 3 Switching off the instrument 21 3 4 Special configurations 21 3 5 Multimeter maintenance 22 4 FUNCTIONAL DESCRIPTION 23 4 1 SEL ON key 23 4 2 RANGE...

Page 5: ...rformed on circuits not directly connected to mains E g protected electronic circuits CAT II Measurement category II is for measurements performed on circuits directly connected to the low voltage ins...

Page 6: ...rent and make sure not to be loaded with static electricity which may destroy internal components Fuses must be replaced with fuses of the same rating and type Any adjustment maintenance or repair wor...

Page 7: ...related software without the explicit authorization of the manufacturer Repairs necessitated by attempts to repair or maintain the product made by a person not approved by the manufacturer Adaptation...

Page 8: ...threshold voltage frequencies duty cycles 2 2 Keypad A six key keypad lets you select the autoranging mode RANGE key freeze a value HOLD key measure fast peaks Pk key set the measurement relative to...

Page 9: ...lly by returning the selector switch to the OFF position or automatically after approximately half an hour if no key is pressed or the switch is not operated Note Automatic shutdown of the instrument...

Page 10: ...n appears on the display the instrument still has approximately 50 hours of operation but specifications can no longer be guaranteed Replace the battery 3 5 3 Replacing the battery or fuses Disconnect...

Page 11: ...sed to access secondary functions associated with the selector switch positions The flowcharts below define these various functions 4 1 1 VAC position 4 1 2 mV position SEL ON SEL ON DC voltage measur...

Page 12: ...imeter 4 1 3 VDC position 4 1 4 position 4 1 5 position SEL ON SEL ON AC DC voltage measurement DC voltage measurement SEL ON SEL ON Continuity test Resistance measurement SEL ON SEL ON Diode voltage...

Page 13: ...RANGE key is used to change from one range voltage to the next range The new range is then displayed for 2 seconds 4 3 REL key Short press Mode REL the last value measured becomes the reference value...

Page 14: ...urement is stable When you remove the probes a second audible signal indicates that this stable value displayed has been stored 4 6 PRINT key This key operates with the optional serial interface for p...

Page 15: ...Serial mode rejection at 50 and 60 Hz better than 60 dB Additional error in Pk mode for a pulse of 1 ms 1 R 50 D For measurements performed on alternative signals the selected range must tally with t...

Page 16: ...1 F2 100 A 1 A 1 5 V 10 A 1 5 R 3 D 2 kHz 1 5 typ 600 VRMS F2 10 mA 30 A 500 mV refer to fuse specifications section 6 1 1 acceptance overload 20 A during 30 s max observing a break 5 min between 2 te...

Page 17: ...threshold voltage measurement Measurable voltages 0 to 2 V Measurement current 1 mA typical Resolution 1 mV Protection 600 VRMS can be reset automatically 5 8 Frequencies Selector switch setting VAC S...

Page 18: ...0 M 0 to 70 from 40 C to 50 C 60 above 50 C Casing and circuit self extinguishing materials Operating quality IEC 359 Electromagnetic compatibility Emission Immunity EN 61326 1 Max influence in electr...

Page 19: ...ps 0 5 to 240 AAC 20 mm MN09 0 1 to 1200 AAC 52 mm CI03 0 5 to 1000 AAC 39 mm PAC 20 0 5 to 1000 AAC 39 mm PAC 21 Shunts 30 A 300 mV HA030 1 50 A 100 mV HA050 Miscellaneous Set of RS232 serial link SX...