Radiance 10/100 Mbps Services Line Card
88
Current – the current transmitter sensor reading.
Min – the lowest power at which the SFP can
continue to operate properly.
Max – the highest power at which the SFP can
continue to operate properly.
Receive Power – indicates the receive power of the
specified port (fiber only) in dBm.
Current – the current receiver sensor reading.
Min – the lowest power at which the SFP can
continue to operate properly.
Max – the highest power at which the SFP can
continue to operate properly.
Example
:
Console> show port 2
Port 2 Information:
Port Type . . . . . . . . . . . . : 100BASE-X
Connector Type . . . . . . . : SFP – LC
SFP Manufacturer . . . : Infineon AG
SFP Part Number . . . : V23848-M305-C56
SFP Serial Number . . : 30010074
SFP Wavelength . . . . : 850 nm
SFP Link Length . . . . : 300 m
SFP Diagnostics . . . . : Internally Calibrated
MAC Address . . . . . . . . : 40:40:9f:18:17:e5
Port AN . . . . . . . . . . . . . : ENABLED
Port Duplex . . . . . . . . . . : FULL
Port Flow Control . . . . . : DISABLED
Port Management . . . . . : ENABLED
Port Speed . . . . . . . . . . . : 100 Mbps
Port State. . . . . . . . . . . . : ENABLED (LINK DOWN)
Port LLCF . . . . . . . . . . . : DISABLED
Port LLR . . . . . . . . . . . . : DISABLED
Port FEF . . . . . . . . . . . . : DISABLED
Temperature (Celsius) : Current: 43
Min: -45
Max: 105 (IN RANGE)
Temperature (Fahrenheit): Current: 109 Min: -49
Max: 221 (IN RANGE)
Transmit Power (dBm) : Current: -6
Min: -9
Max: 0
(IN RANGE)
Receive Power (dBm) : Current: -35
Min: -20
Max: 0
**OUT OF
RANGE**
Console>
show
portstatistics
Description
: Show MIB-II interface statistics for one port or all three
ports.
Syntax
:
show portstatistics <port number | all>
Parameters
: port number – the actual port number.
all – specifies all ports.
Display
Parameters
: Octets Received – number of octets received.
Unicast Packets Rcv’d – number of unicast packets
received.
Broadcast Packets Rcv’d – number of broadcast packets