Page 3: ...rologic com Hampshire RG21 6XG ASIA Singapore Metrologic Asia Pte Ltd Tel 65 842 7155 No 8 Kaki Bukit Place Fax 65 842 7166 4 th Floor Email info sg metrologic com Singapore 416186 China Metro Suzhou Technologies Co Ltd Tel 86 512 62572511 221 Xing Hai Street Fax 86 512 62571517 Suzhou Industrial Park Email info cn metrologic com Suzhou China 215021 Japan Metrologic Japan Co Ltd Tel 81 3 3839 8511...

Page 4: ... Scanner 8 Scanner Parts 9 Audible Indicators 10 Visual Indicators 11 Failure Modes 12 Scan Area 13 Labels 14 Troubleshooting Guide 15 RS 232 Demonstration Program 19 Maintenance 19 Appendix A Specifications 20 Appendix B Default Settings 22 Appendix C Scanner Pinout Connections 27 Cable Connector Configurations 29 Appendix D Warranty and Disclaimer 31 Appendix E Notices 31 Appendix F Patent Infor...

Page 5: ... a wider scan field than a typcial CCD The width of the scan line grows as the scanner moves further away from bar codes In addition the laser beam pulses making lining up bar codes easy and when the scanner senses a bar code CodeSense Mode the laser beam automatically switches to scan mode and activates CodeGate to ensure high speed scanning and accuracy Many of the standard features include Powe...

Page 6: ...power jack MLPN 55 55002A PS2 Keyboard Cable 2 4m 8 straight cord long bend relief with built in power jack MLPN 55 55142A PS2 Keyboard Cable 1 5m 5 straight cord long bend relief without built in power jack MLPN 55 55166A Stand Alone Keyboard Cable 2 1m 7 straight cord long bend relief with built in power jack MLPN 55 55020A Stand Alone Keyboard Cable 1 5m 5 straight cord long bend relief without...

Page 7: ...links during power save mode Operational Test 6 Place a bar code in front of the scanning window While aiming at the bar code with the blinking laser beam press the CodeGate button scanner will beep once and flash the red LED if the bar code was successfully decoded 7 The scanner is shipped from the factory programmed with default settings To configure the MS5145 scanner to meet the host system s ...

Page 8: ... will beep once Manufacturer s Note Plugging the scanner into a port on the host system does not guarantee that the scanned information will be communicated properly to the host system The scanner and or the host system may need to be configured for communications to occur Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for ...

Page 9: ...e L shaped plug of the power supply into the power jack on the PowerLink cable refer to the manufacturer s recommendation and Note on page 6 5 Make sure the AC input requirements of the power supply match the AC outlet Connect the power supply into an AC outlet see caution statement on page 6 6 The PowerLink Y cable is terminated with a 5 pin DIN female connector on one end and a 6 pin mini DIN ma...

Page 10: ...ment on page 5 Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN 60950 To maintain compliance with standard CSA C22 2 No 60950 UL 60950 and norm EN 60950 the power source should meet applicable performance requirements for a limited power source To maintain compliance with fede...

Page 11: ... Note The MS5145 USB scanner will receive power directly from the host system no external power supply is required 2 Connect the USB connector of the PowerLink cable into the USB port of the host system 3 When the MS5145 is ready to scan the green LED will turn on the red LED will flash and the scanner will beep once n o ...

Page 12: ...r supply has been disconnected from the PowerLink cable 1 Locate the small pin hole on the back of the scanner 2 Bend an ordinary paperclip into the shape shown above 3 Insert the paperclip or other small metallic pin into the small pin hole 4 You will hear a faint click Pull gently on the strain relief of the PowerLink cable and it will slide out of the scanner o p q n ...

Page 13: ...and scanning operation and it blinks during power save mode On a successful read of a bar code the red LED will flash and the scanner will beep once The LEDs are also used as diagnostic indicators and mode indicators 2 Output Window Laser Light emits from this aperture 3 PowerLink Cable The 10 pin modular plug on the PowerLink cable connects into the 10 pin modular jack on the MS5145 ...

Page 14: ...grammed to do so If the scanner does not beep once and the red light does not flash then the bar code has not been successfully read Three Beeps during operation When entering the program mode the red LED will flash while the scanner simultaneously beeps three times The red LED will continue to flash until the unit exits program mode Upon exiting program mode the scanner will beep three times and ...

Page 15: ...ld the scanner will wake up and return to normal pulse mode Steady Green and Single Red Flash When the scanner successfully reads a bar code the red LED will flash and the scanner will beep If the red LED does not flash and the scanner does not beep then the bar code has not been successfully read Steady Green and Steady Red After a successful read the scanner transmits the data to the host device...

Page 16: ...with all LEDs off If upon power up the scanner emits a continuous razzberry tone then the scanner has an experienced an electronic failure Return the unit for repair to a Metrologic Authorized Service Center Three Beeps on power up If the scanner beeps 3 times on power up then the non volatile memory NovRAM that holds the scanner configuration has failed Return the unit for repair to a Metrologic ...

Page 17: ...13 SCAN AREA Minimum Bar Code Element Width A B C D E F mm 10 12 17 26 33 66 mils 4 1 4 8 6 8 10 4 13 26 ...

Page 18: ...e of manufacture serial number laser and caution information The following is an example of this label Patent Information See Manual FCC and ICES 003 Information See Manual Warranty VOID if case opened Contains no user serviceable components Complies with 21 CFR 1040 10 1040 11 IEC 60825 1 1993 A2 2001 ...

Page 19: ...ost systems cannot supply enough current to power the MS5145 Use the proper power supply 3 beeps on power up Non volatile RAM failure Contact a Metrologic Representative if the unit will not hold the programmed configuration Continuous razz tone on power up RAM or ROM failure Contact a Metrologic Representative Razz tone at power up VLD failure or a Scanner flipper failure Contact a Metrologic Rep...

Page 20: ...code but locks up after the first scan and the red LED stays on The scanner is configured to support some form of host handshaking but is not receiving the signal If the scanner is setup to support ACK NAK RTS CTS XON XOFF or D E verify that the host cable and host are supporting the handshaking properly The unit scans but the data transmitted to the host is incorrect The scanner s data format doe...

Page 21: ...check digits are set properly Scanner beeps at some bar codes and NOT for others of the same bar code symbology The minimum symbol length setting does not work with the bar code Check if the correct minimum symbol length is set The unit scans the bar code but there is no data Configuration is not correct Make sure the scanner is configured for the appropriate communication mode The unit scans but ...

Page 22: ...okup table Try operating the scanner in Alt mode Power up OK and scans OK but does not communicate properly to the host Com port at the host is not working or configured properly or Cable not connected to the proper comm port Check to make sure that the baud rate data bits stop bits and parity of the scanner and the communication port match and the program is looking for RS 232 data The host is re...

Page 23: ... that will take RS 232 data and place it into a keyboard buffer may be needed This program tells the PC to ignore RTS CTS Data Set Ready DSR and Data Carrier Detect DCD signals If the demonstration program works and yours still does not jumper RTS to CTS and Data Terminal Ready DTR to DCD and DSR on the back of your PC 10 CLS 20 ON ERROR GOTO 100 30 OPEN COM1 9600 S 7 1 CS0 DS0 CD0 LF AS 1 35 PRIN...

Page 24: ...System Interfaces RS232 Keyboard Wedge Light Pen Emulation IBM 468X 469X OCIA Stand Alone Keyboard USB Print Contrast 35 minimum reflectance difference Number Characters Read Up to 80 data characters Maximum number will vary based on symbology and density Roll Pitch Yaw 42 68 52 Beeper Operation 7 tones or no beep Indicators LED Green laser on ready to scan Red good read MECHANICAL Length 170 mm 6...

Page 25: ...s II IEC 60825 1 1993 A1 1997 A2 2001 Class 1 EMC Class B FCC Part 15 ICES 003 European Union Directive ENVIRONMENTAL Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 40 C to 60 C 40 F to 140 F Humidity 5 to 95 relative humidity non condensing Light Levels Up to 4842 Lux 450 footcandles Shock Designed to withstand 1 5 m 5 drops Contaminants Sealed to resist airborne particulate ...

Page 26: ...does not support every parameter If the communication supports a parameter listed in the charts on the following pages a check mark will appear Parameter Default OCIA RS232 Light Pen IBM 46XX KBW USB Normal Scan Mode Blink 9 9 9 9 9 9 Continuous Scan Mode 9 9 9 9 9 9 UPC EAN 9 9 9 9 9 9 UPC A 9 9 9 9 9 9 EAN 8 9 9 9 9 9 9 EAN 13 9 9 9 9 9 9 UPC E 9 9 9 9 9 9 Code 128 9 9 9 9 9 9 Code 93 9 9 9 9 9 ...

Page 27: ...eeper Tone Normal 9 9 9 9 9 9 Beep Transmit Sequence Before transmit 9 9 9 9 9 Communication Timeout none 9 9 9 9 9 Razzberry tone on Timeout 9 9 9 9 9 Three beeps on Timeout 9 9 9 9 9 Same symbol rescan timeout 100 msecs 9 9 9 9 9 9 Same symbol rescan timeout 200 msecs 9 9 9 9 9 9 Same symbol rescan timeout 500 msecs 9 9 9 9 9 9 Same symbol rescan timeout 1200 msecs 9 9 9 9 9 9 Same symbol rescan...

Page 28: ...umber system 9 9 9 9 9 Transmit UPC A Manufacturer ID 9 9 9 9 9 Transmit UPC A Item ID 9 9 9 9 9 Transmit Codabar Start Stop Characters 9 9 9 9 CLSI Editing Enable 9 9 9 9 Transmit Mod 10 ITF 9 9 9 9 Transmit MSI Plessy 9 9 9 9 Parity Space 9 9 Baud Rate 9600 9 8 Data Bits 9 9 7 Data Bits 9 Stop Bits 2 9 9 Manufacturer s ID 9 9 9 Scanner ID 9 9 9 Transmit Sanyo ID Characters 9 9 9 Nixdorf ID 9 9 9...

Page 29: ...TX prefix 9 9 ETX suffix 9 9 9 DE Disable Command 9 FL Laser Commands 9 DTR Handshaking support 9 RTS CTS Handshaking 9 Character RTS CTS 9 Message RTS CTS 9 XON XOFF Handshaking 9 ACK NAK 9 Two Digit Supplements 9 9 As Code 39 9 9 9 Five Digit Supplements 9 9 As Code 39 9 9 9 Bookland 978 9 9 As Code 39 9 9 9 977 2 digit Supplemental Requirement 9 9 9 9 9 9 Supplements are not Required 9 9 9 9 9 ...

Page 30: ...Programmable Code Lengths 7 avail 9 9 9 9 9 9 Programmable Suffix Characters 10 avail 9 9 9 Prefixes for Individual Code types 9 9 9 Inter Scan Code Delay Programmable 100 µsec steps 800 µsec 9 Function Control Key Support 9 9 Minimum Element Width Programmable in 5 6 µsec steps 1 msec 9 Country Coded Keyboards US 9 9 ...

Page 31: ...27 APPENDIX C Scanner Pinout Connections MS5145 41 RS 232C LTPN Pin Function 1 Ground 2 RS 232 Transmit Output 3 RS 232 Receive Input ...

Page 32: ...ctor Configurations RS232 PowerLink Cable with built in power jack MLPN 55 55000A The RS232 PowerLink cable is terminated with a 9 pin D Type connector to the host Standard PowerLink cable Pin Function 1 Shield Ground 2 RS 232 Transmit Output 3 RS 232 Receive Input 4 DTR Input Light Pen Source 5 Power Signal Ground 6 Light Pen Data 7 CTS Input 8 RTS Output 9 5VDC ...

Page 33: ...eyboard and the keyboard port on the PC The pin assignments of the Keyboard Wedge PowerLink and adapter cable are as follows POWERLINK CABLE ADAPTER CABLE 5 pin Female DIN 5 pin Male DIN Pin Function Pin Function 1 Keyboard Clock 1 PC Clock 2 Keyboard Data 2 PC Data 3 No Connect 3 No Connect 4 Power Ground 4 Power Ground 5 5 Volts DC 5 5 Volts DC 6 pin Male Mini DIN 6 pin Female Mini DIN Pin Funct...

Page 34: ...PPENDIX C CONTINUED USB PowerLink cable MLPN 55 55165A The USB PowerLink cable is terminated with an USB A type connector USB PowerLink cable Pin Function 1 PC 5V V_USB 2 D 3 D 4 Ground USB A Type Connector ...

Page 35: ...ect improper installation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened by anyone other than Metrologic s repair department or authorized repair centers THIS LIMITED WARRANTY EXCEPT AS TO TITLE IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES EITHER EXP...

Page 36: ...beam even if the scanner appears to be nonfunctional Never open the scanner in an attempt to look into the device Doing so could result in hazardous laser light exposure The use of optical instruments with the laser equipment will increase eye hazard Remarque Cet appareil numerique de la class B est conforme à la norme NMB 003 du Canada Attention L emploi de commandes réglages ou procédés autres q...

Page 37: ...y or by implication estoppel or otherwise under any METROLOGIC or third party intellectual property rights whether or not such third party rights are licensed to METROLOGIC including any third party patent listed above except for an implied license only for the normal intended use of the specific equipment circuits and devices represented by or contained in the METROLOGIC products that are physica...

Page 38: ... 6 28 30 Configuration 1 2 9 11 14 18 26 Current 6 14 20 Customer service 2 28 D DC transformer 20 Decode capability 19 Default settings 3 21 Depth of field 1 Design specifications 19 Disclaimer 28 E Electrical power supply 3 7 14 26 F Failure indicator s 9 11 14 Failure modes 11 G Green LED 3 4 8 10 19 H Host 3 4 6 7 10 14 17 26 I Indicators 8 9 10 19 Input voltage 4 6 20 Installation 2 4 6 28 In...

Page 39: ... tone 9 10 11 22 Red LED 3 4 6 8 9 10 Repair 11 28 RMA 28 RS 232 1 17 18 19 21 26 S Scan lines 19 Scan speed 19 SELV 4 6 Service 11 28 Specifications 19 T Tones 9 19 Transformers 20 Troubleshooting 14 15 16 17 U USB 1 28 30 V Ventilation 20 Visual 10 Voltage 20 W Warranty 28 Weight 19 Window 3 8 13 ...

Page 40: ...June 2002 7 0 7 9 0 0 1 B ...