Aux Port Configuration Cable
*
,
MLPN
57-57008
x
-N-3
Pin
Function
**
1
No Connect
2
Output from Scanner
3
Input to Scanner
4
No Connect
5 Ground
6
No Connect
7
No Connect
8
No Connect
9
No Connect
9-Pin D-Type Connector
RS232 LSO/AUX Cable,
MLPN
57-57099
x
-3
Pin
Function
†
1 Signal
Ground
2
RS232 from Aux / Secondary Scanner
3
RS232 to Aux / Secondary Scanner
4
RTS from Aux / Secondary Scanner
5
CTS to Aux / Secondary Scanner
6
No Connect
7
No Connect
8
No Connect
9
+5VDC – Transformer / Direct
10 Shield
Ground
10-Position Angled Modular Plug
*
This configuration cable was designed to be used with the MS2421/MS2422 auxiliary connector only.
**
All signals are referenced from the MS2421/MS2422 scanner.
†
All signals are referenced from the auxiliary / secondary scanner.