Electrical installation
Page 61
Product Manual / Mounting Instructions
„Servo drives ARS 2320 FS, ARS 2340 FS and ARS 2360W FS“
Version 1.0
The ARS 2300 FS servo positioning controller has one differential (AIN 0) and two single-ended analogue
inputs for input voltages in the range of
10 V. The inputs AIN 0 and #AIN 0 are led to the control system
via twisted cables (twisted-pair type). If the control system is equipped with single-ended outputs, the
output is connected to AIN 0 and #AIN 0 is connected to the reference potential of the control system. If
the control system is equipped with differential outputs, they are to be connected 1:1 to the differential
inputs of the ARS 2300 FS servo positioning controller.
The reference potential AGND is connected to the reference potential of the control system. This is
necessary in order to prevent the differential input of the ARS 2300 FS servo positioning controller from
being overridden by high "common-mode interference".
There are two analogue monitor outputs with output voltages in the range of
10 V and one output for a
reference voltage of +10 V. These outputs can be led to the superordinate control system; the reference
potential AGND must be carried along. If the control system is equipped with differential inputs, the "+"
input of the control system is connected to the output of the ARS 2300 FS servo positioning controller and
the "-" input of the control system to AGND.
Mating plug X1
INFORMATION
Mating plug
ARS 2320/40/60W FS
X1
D-SUB connector, 25-pin type, male
Housing for a 25-pin D-SUB connector with locking screws of type 4/40 UNC
Recommended cable type or comparable:
LAPP KABEL UNITRONIC LiYCY (TP); 25 x 0.25 mm²;
10.7 mm