15 Appendix
15.6
Error messages and warnings
Group 0: Events
0-0
Invalid error
An invalid (corrupted) entry in the error buffer has
been marked with this error number.
Entry in the permanent event memory. No
measures required.
0-1
Invalid error detected
and corrected
An invalid (corrupted) error entry has been
detected and corrected in the error buffer. The
debug information includes the original error
number.
Entry in the permanent event memory. No
measures required.
0-2
Error cleared
The active errors have been acknowledged.
Entry in the permanent event memory. No
measures required.
0-4
Serial number / device
type (module
replacement)
A replaceable error memory module (service
module) has been plugged into another device.
Entry in the permanent event memory. No
measures required.
0-7
Additional log entry
Entry in the permanent event memory. No
measures required.
0-8
Servo drive switched on Log entry proving that the servo drive has been
switched on.
Entry in the permanent event memory. No
measures required.
0-9
Servo drive: safety
parameters changed
Logging of the parameterisation of the FSM 2.0 -
MOV.
Entry in the permanent event memory. No
measures required.
0-11
FSM module
replacement (previous
type)
Logging of the module replacement.
Entry in the permanent event memory. No
measures required.
0-12
FSM module
replacement (current
type)
Logging of the module replacement.
Entry in the permanent event memory. No
measures required.
0-21
Log entry from the FSM
Logging of events in the FSM.
Entry in the permanent event memory. No
measures required.
0-22
Default parameter set
loaded
Log entry proving that the default parameter set
has been loaded.
Entry in the permanent event memory. No
measures required.
Group 1: Stack overflow
1-0
Stack overflow
Incorrect firmware?
Load the most recent firmware.
Please contact the Technical Support team.
Product manual BL 4000-C
Page 268 of 298