7 Additional settings
7.5.2
"X2A" tab
Figure 81: "Angle encoder settings" window - "X2A" tab
This tab is used for the parameterisation of an angle encoder connected to X2A. This can
either be a resolver or an encoder with analogue Hall sensors. Single- and multi-pole
resolvers are supported. For special applications, additional adaptations can be realised
based on a gear factor to convert the angle into the actual position. In general, this is not
necessary in the case of common motor/resolver combinations.
If the checkbox
active
is ticked, the firmware will analyse the encoder information
provided via this connection. The checkbox must be ticked if the angle encoder is used for
commutation and/or for determining position or speed values.
The default setting for the
Gear factor
is 1:1. These settings apply only to a gear factor
between angle encoder and motor. If you want to parameterise an application with a gear
unit, specify this gear factor under
Display units
to get parameters in the units of the driven
side (output).
In the drop-down menu
Mode
, specify whether a resolver or an analogue Hall sensor is
connected to X2A.
Product manual BL 4000-C
Page 135 of 298