05/01
10-09-B
NORDBERG LT105/105S INSTRUCTION MANUAL
10-1
SERVICE INSTRUCTIONS
CHAPER
10
10.1 GENERAL
Only skilled and experienced mechanics must be
allowed to service the plant.
In any work related to the operation, adaptation to
manufacture, conversion or adjustment of the
Lokotrack and its safety equipment, as well as to
inspection, maintenance and repair, observe starting
and stopping procedures in accordance with the
Instruction Manual and any indications relating to
maintenance work!
Secure extensively, as far as necessary, the area of
maintenance works!
In case the Lokotrack is completely switched off
during maintenance and repair works, it must be
safeguarded against unexpected switching-on.
Lock-up main starting equipment, draw off keys
and affix a hazard pictorial at the main switch.
Smoking and any open flame is prohibited in the
immediate area of the machine when refuelling or
servicing the fuel system.
In case of fire:
–
Move the Lokotrack away from the
dangerous area
–
Stop the engine
–
Turn off the main switch
–
Start fire fighting and give the alarm if
necessary.
Diesel fuel is flammable - do not use as cleaning
fluid. Use solvents of accepted quality only.
Always stop the engine during maintenance unless
it is mentioned in the instruction manual to keep the
engine running.
Do not check for leaks with a bare hand, use
suitable cleaning cloth.
Never adjust any hydraulic valve beyond the
pressure recommended by the manufacturer.
Always ensure adequate ventilation when running
the engine in a confined area.
Remember that some solvent qualities may cause
skin irritation and may be extremely inflammable.
Avoid breathing of solvent fumes.
Service facilities must be kept clean. Oil and water
can make floors slippery and highly dangerous.
Avoid severely soiled clothing, they can be a fire
hazard.
Keep the Lokotrack and equipment free from oil
spillage and dust. A clean machine reduces the fire
risk and simplifies visual checks for components
requiring attention.
Be careful when using pressure cleaning
equipment. Even low pressures and temperatures
can damage wire insulation.
Check wiring for signs of abrasion damage or
kinks. This can cause short circuits and fire.
Check hydraulic hoses for abrasion damage or
kinks.
Never weld or grind containers of inflammable
liquids.
Always have a fire extinguisher on hand when
carrying out welding or grinding operations.
Notify the location and use of fire extinguishers.