6 Technical Data
page 20
ELC N6_N10-V3.1-09/11-GB subject to technical alterations
6 Technical
Data
General data ELC
mains frequency
50 / 60 Hz
tolerance mains voltage
nominal voltage ± 10 %
recommended air flow
120 m
3
/ h per ballast
Control range
approx. 20 - 100 %
Firing voltage
2000 V / < 1 sek.
Protection IP
20
Ambient temperature
0°C to +40°C in operation
-20°C to +70°C during storage and transportation, before initial operation leave
at least 4 hrs at room temperature
Permissible pollution
pollution severity 2 according to VDE 0110
Permissible humidity
relative atmospheric humidity 80 %, non-condensing
Dimensions (H x W x D)
approximately 500 x 320 x 130 mm
Weight approximately
16
kg
Installation position
only vertical (lamp and power connection at the top; control connections at the
bottom) respecting the minimum spacing in 3.1
EMC
Verified according to
EN 55011
EN 61000-3-3
EN 61000-6-2
Safety
Verified according to
EN 50178
Leakage current
Leakage current > 3 mA, see Chapter 1 “Safety“