3. Installation
page 6
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
3.1.2.
Horizontal installation position
Fig. 2:
Assembly of the ELC, horizontal installation position (all dimensions in mm).
3.2.
Power connections
L3
out1
L1 L2
L1
L2
L3
N
PE
out2
earthed lead network side
automatic cutout
cable shield
lamp feeder cable
lamp assembly
ELC
power choke
Fig. 3:
Power connections
Fig. 3 shows the electrical installation.
Operation of the ballasts requires a power
choke in series (see technical data chapter 6)
in order to limit the total harmonic distortion
of the line current to below 50%.
The lamp feeder cable shielding must be
connected to the ELC. To this end the
connector has an EMC screw connection (also
see: connection lamp cable).
If wished, the shielding can also be
connected to the lamp unit.
Mains supply cables and lamp feeder cables must be laid separately from
control cables.