3. Installation
page 7
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
3.2.1.
Mains connection
The cross section of the earthed wire must be at least 10 mm². The three phases must be
provided with an automatic cutout.
In order to avoid damaging the terminal pins, please do not exceed the
following torques:
PE22B:
Line:
Torque:
L1, L2, L3:
1.5
–
1.8 Nm
Grounding conductor (PE):
3.0
–
4.0 Nm
PE35B:
Line:
Torque:
L1, L2, L3:
2.0
–
2.3 Nm
Grounding conductor (PE):
2.0
–
2.3 Nm
3.2.2.
Connecting the lamp feeder cable
The lamp feeder cable must correspond with the cable parameters described in
chapter 6.
Components of the connector:
connector module
hood
crimp contacts
EMC cable gland with
plastic insert