4. Operation of ELC
page 26
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
4.7.
Use of the control outputs
“
Digital I/O
”
4.7.1.
User Register
Via the [User Register] of the PROFIBUS-output-data the outputs DO1 (pin X6.1) and DO2 (pin
X6.2) may be operated. If the
{DO1}
-bit in the
[User Register]
is set to 1 the output DO1 on
connector X6 is pulled to ground, if set to 0 the output is high impedance. The
{DO2}
-bit
functions accordingly for output DO2.
PROFIBUS-output-data (Master
→
ELC)
Byte-
No.
0
1
2
3
4
5
Name
[Power
Set
Value]
[Installed
Lamp
Power]
[Lamp
Control]
[User
Register]
↓
Bit
7
6
5
4
3
2
1
0
Name
n/a n/a n/a n/a n/a
DO2 DO1
n/a
Example:
In case of a PE35B-cabinet the outputs are used as follows:
DO1 is connected to the cabinet-operation-indicator (1 = indicator on, 0 = indicator off).