56
Fault correction
Remedy
Fault
Cause
The battery indicator
blinks after the switch-
on.
Battery indicator on the
operating module does
not light up after the
switch-on.
Plug connection at one
of the drives without
contact.
Power motors are
switched to push mode.
Check the plug connec-
tions.
Move the selection lever
for the drive motors into
the drive mode position
and make sure it clicks
into place.
Battery fuse is defective
or not correctly inserted.
Replace defective fuse or
clean contacts and insert
correctly.
Malfunction in the elec-
tronics.
Have the fault corrected
by an authorised work-
shop. (Push mode)
Selection lever in driving
mode position.
Lighting not active.
Filament bulb defective.
Lighting electronic de-
fective.
Replace defective fi la-
ment bulb.
Let it be repaired or re-
placed by a specialist
workshop.
Not listed faults.
View <
fault diagnosis
>
in the operating manual
for the operating mod-
ule.
Check the plug connec-
tions.
Plug connection of the
power supply without
contact.