34
APPENDIX C
AUDIO INPUT
Type
Differential, electronically balanced
Max. common mode range
±15 V DC, clamped to earth for voltage transient protection
Connectors
Female XLR input with male XLR loop output or VEAM all-in-one connector (integrates AC,
audio, and network)
Input impedance
10 k
Ω
differential between pins 2 and 3
Wiring
Pin 1: Chassis/earth through 220 k
Ω
, 1000 pF, 15 V clamp network to provide virtual
ground lift at audio frequencies
Pin 2:
Pin 3: Signal -
Case: Earth ground and chassis
DC Blocking
Differential DC blocking up to max common mode voltage
CMRR
>50 dB, typically 80 dB (50 Hz – 500 Hz)
RF filter
Common mode: 425 kHz
Differential mode: 142 kHz
TIM filter
<80 kHz, integral to signal processing
Nominal input sensitivity
0 dB V (1 V rms, 1.4 V pk) continuous is typically the onset of limiting for noise and music.
Input level
Audio source must be capable of pro20 dBV (10 V rms, 14 V pk) into 600
Ω
in
order to produce maximum peak SPL over the operating bandwidth of the loudspeaker
AMPLIFIERS
Amplifier type
Three-channel complementary MOSFET output stages (class AB/H)
Output power
1275 W (three channels; 2 x 500 W, 1 x 275 W); 2550 W peak
Note:
Amplifier wattage rating based on the maximum unclipped burst sine-wave rms
voltage that the amplifier will produce for at least 0.5 seconds into the nominal load
impedance: 45 V rms low channels and 47 V rms high channel. Peak power based on
the maximum unclipped peak voltage that the amplifier will produce for at least 100
milliseconds into the nominal load impedance: 63 V peak low channels and 67 V peak high
channel.
THD, IM TIM
< .02%
Load capacity
4
Ω
low and mid; 8
Ω
high channels
Cooling
Convection cooled
AC POWER
AC power connector
PowerCon with looping output or VEAM
Voltage selection
Automatic, two ranges, each with high-low voltage tap (uninterrupted)
Safety agency rated
operating voltage
95 V AC – 125 V AC, 208 V AC - 235 V AC, 50/60 Hz
Turn on/turn off points
85 V AC - 134 V AC; 165 V AC - 264 V AC
Current Draw
Idle current
.680 A rms (115 V AC), .360 A rms (230 V AC), .760 A rms (100 V AC)
Max. long-term continuous
current (>10 sec)
2.3 A rms (115 V AC); 1.2 A rms (230 V AC); 2.6 A rms (100 V AC)
Burst Current (<1 sec)
4 A rms (115 V AC), 2 A rms (230 V AC), 4.5 A rms (100 V AC)
Note:
AC power cabling must be of sufficient gauge so that under burst current RMS conditions, cable transmission
losses do not drop voltage below specified operating range at the speaker.
Ultimate Short-Term Peak
Current Draw
13 A pk (115 V AC), 6.5 A pk (230 V AC), 15 A pk (100 V AC)
Inrush Current
10 A pk (115 and 100 V AC), 18 A pk (230 V AC)
RMS NETWORK
Equipped with two-conductor twisted-pair network, reporting all operating parameters of
amplifiers to system operator’s host computer.
Summary of Contents for M'elodie
Page 8: ...2 INTRODUCTION ...
Page 20: ...14 CHAPTER 3 ...
Page 42: ...36 APPENDIX C ...