44
Fault correction
Fault
Cause
Remedy
Battery indicator on the
operating module does
not light up after the
switch-on.
Battery fuse is defective or
not correctly inserted.
Replace defective fuse or
clean contacts and insert
correctly.
Plug connection of the
power supply without
contact.
Check the plug connec-
tions.
The battery gauge blinks
after the switch-on.
Drive switched to push
mode.
Swivel the selection le-
ver drive- / push mode to
drive mode.
Plugged connection on
the drive misses contact.
Check plugged connec-
tion.
Malfunction in the elec-
tronics.
Have it repaired by the
specialist workshop. (Push
mode).
Selection lever in driving
mode position.
Not listed faults.
View <
Error diagnostics
>
in the operating manual
for the operating module.
Lighting not active.
Filament bulb defective.
Replace light bulb or have
it repaired, resp. replaced
in a specialist workshop.
Lighting fuse or drive elec-
tronics defective.
Let it be repaired or re-
placed by a specialist
workshop.