Figure 2: RFI Suppression

Table 1: Suppression by Band

Band

Peak Suppression

160 m

-60 dBm

80 m

-51 dBm

60 m

-46 dBm

40 m

-48 dBm

30 m

-24 dBm

20 m

-30 dBm

17 m

-20 dBm

15 m

-29 dBm

12 m

-15 dBm

10 m

-24 dBm

6 m

-25 dBm

-2-

Summary of Contents for MFJ-1146

Page 1: ...RF Filtered DC Outlets MFJ 1146 INSTRUCTION MANUAL c 2020 MFJ Enterprises Inc 300 Industrial Park Rd Starkville MS 39759 P 662 323 5869 F 662 323 6551...

Page 2: ...l handbooks or other official publications The copy of this manual provided to the customer will not be updated to reflect current data Customers using this manual should report errors or omissions re...

Page 3: ...TRODUCTION 1 1 2 FEATURES 1 1 3 CONNECTIONS 3 1 4 INSTALLATION 3 2 TECHNICAL ASSISTANCE 4 List of Figures 1 The MFJ 1146 RF Filtered DC OutletsTM 1 2 RFI Suppression 2 3 MFJ 1146 Connections 3 4 Stati...

Page 4: ...FI out With four sets of Anderson powerpoles and two sets of high current binding posts the MFJ 1146 is versatile enough for all of your power needs Figure 1 The MFJ 1146 RF Filtered DC OutletsTM 1 2...

Page 5: ...truction Technical Manual Figure 2 RFI Suppression Table 1 Suppression by Band Band Peak Suppression 160 m 60 dBm 80 m 51 dBm 60 m 46 dBm 40 m 48 dBm 30 m 24 dBm 20 m 30 dBm 17 m 20 dBm 15 m 29 dBm 12...

Page 6: ...Poles 4 Binding Posts 5 Safety RFI Ground 1 4 INSTALLATION A simple station setup using the MFJ 1146 is shown in Figure 4 Place the MFJ 1146 between your power supply and your radio while keeping the...

Page 7: ...0549 or the MFJ Factory at 662 323 5869 You will be best helped if you have your unit manual and all information on your station handy so you can answer any questions the technicians may ask You can...

Page 8: ...USER NOTES...

Reviews: