Battery Installation and Replacement:  

Use any fresh 9-volt flat-pack type battery (not 

supplied).  To install, remove screw from each side of case and gently separate two 
halves.  Install 9-volt battery on snap clip, then slip into retainer (see previous drawing).   
To prevent damage from battery leakage, always remove battery when storing meter for 
prolonged periods.   

 

  
Important Note:  Always remove the battery when storing your unit for long periods.
 
 
Operating Instructions 
 
Using the Sense Coil:  

The sense coil snaps over wires and cables, as shown below.  To 

unlatch, squeeze the nylon carrier between thumb and forefinger--applying opposing 
pressure.  The coil's top section should move forward slightly.  With pressure applied, lift 
up to open.  Position the wire or cable inside the core opening.  Close the lid over the 
cable, pressing down until latch clicks shut.   

 

1

2

3

Click!

Lift

Press

Unlatch

 

 
Meter:  

The

 

meter is scaled from 0 to 100.  On the 100-mA range, readout is direct (100 

= 100 mA).  On the 1-A range, move the decimal point 2 places to the left (100 = 1.00 A).  
To convert meter readings made on the 30 mA, 300 mA, and 3-A ranges, multiply 
accordingly.  For example, a reading of 85 on the 300-mA range equals 300 x .85, or 255 
mA.   The chart below will help you estimate readings quickly: 
 

                            

Meter

Range

10

3

30

0.3

20

6

60

0.6

30

9

90

0.9

40

12

120

1.2

50

15

150

1.5

60

18

180

1.8

70

21

210

2.1

80

24

240

2.4

90

27

270

2.7

100

30

300

3.0

10
20
30
40
50
60
70
80
90

100

0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0

30 mA

100 mA

300 mA

1 A

3 A

 

 
The <30 mA range is uncalibrated and meter readings represent a relative indication only.  
It is normal, at high sensitivity, to see some residual meter reading (up to 15%). 

Summary of Contents for MFJ-854

Page 1: ...ode compensated Op Amp delivers improved meter linearity Rugged Built to last with a sturdy all aluminum case and G 10 pc board Battery Saver Press to test power circuit turns unit off automatically after 15 seconds Long Battery Life Meter draws 3 mA battery s service life approaches shelf life Handheld Size Weighs 11 ounces only 2 3 x 1 6 x 6 5 including sense coil Controls and Locations Sensitiv...

Page 2: ...n the wire or cable inside the core opening Close the lid over the cable pressing down until latch clicks shut 1 2 3 Click Lift Press Unlatch Meter The meter is scaled from 0 to 100 On the 100 mA range readout is direct 100 100 mA On the 1 A range move the decimal point 2 places to the left 100 1 00 A To convert meter readings made on the 30 mA 300 mA and 3 A ranges multiply accordingly For exampl...

Page 3: ... normal Power Switch Power is applied via a press to test momentary contact switch A built in hold circuit keeps the unit powered for approximately 15 20 seconds after the switch is released This feature permits hands off measurement on energized conductors RF Hazard Important Warnings 1 RF current measurements must be conducted with extreme caution Physical contact with conductors carrying even m...

Page 4: ... problem always check battery condition first If battery replacement fails to resolve the problem you may contact MFJ Customer Service by phone at 601 323 5869 or reach them via E mail at mfj mfjenterprises com Be sure to include a complete description of the difficulty Calibration Instructions To check meter calibration use the test set up shown below HF Transceiver In Line Wattmeter 7 000 MFJ 85...

Page 5: ...Schematic Parts List ...

Reviews: