CS 300 RM Gate Controls / Rev. B 1.0 – 17
9.2 Input operating mode
Function
Description
Possible settings
Factory setting
ENGLISH
Select the menu language
DEUTSCH
ENGLISH
FRANCAIS
ESPANOL
NEDERLANDS
POLSKI
CESKY
ITALIANO
ENGLISH
RUNNING-
TIME
Monitors the maximum running time for an open and close movement
1 – 250 seconds
60 seconds
OPEN TIME
After the door has opened, it runs in the CLOSE direction again after the set time has
elapsed.
Open time > 0 = impulse functions only in the OPEN direction
0 – 600 seconds
0 =
Auto close off
FOREWAR-
NING
The traffic light flashes before the door starts to close.
The preset forewarning time is only active if the open time is > 0 or if operated via
radio impulse.
0 – 120 seconds
0 = Off
REVERS.
TIME
Time spent stationary each time the door changes direction
0.1 - 2.0 seconds (in
1/10 second steps)
0.3 seconds
MOD1-3
STANDBY
MOD 1:
OFF when resting
MOD 2:
ON when resting
MOD1
MOD2
MOD1
FAST CL.
ON:
The open time is interrupted after a vehicle passes the light barrier (the
door then closes immediately).This function is also active if the open time
is set to 0.
OFF:
The open time continues as usual
ON
OFF
OFF
RELAY 1
RELAY 2
RELAY 3
RELAY 4
All 4 relays can have a relay module of 1 to 28 assigned to them.
MOD1:
Red traffic light lights up during door movement and flashes as a war
-
ning before door movement starts
MOD2:
Red traffic light flashes during door movement and as a warning before
door movement starts
MOD3:
Red traffic light lights up during door movement and as a warning before
door movement starts
These 3 modes are affected by the parameter M1-3 STANDBY
MOD4:
Impulse when OPEN command is given
MOD5:
Error message
MOD6:
OPEN end position
MOD7:
CLOSE end position
MOD8:
OPEN end position negated
MOD9:
CLOSE end position negated
MOD11: Pre-limit position CLOSE
MOD12: Pre-limit CLOSE position to CLOSE end position
MOD13: Magnetic lock function
MOD14: Brake
MOD15: Brake negated
MOD16: Brake remains ON during open time
MOD17: Safety edge protection (SKS) activated
MOD18: (Red traffic light 4)
Forewarning - flashing
Door movement - off
MOD20: Activation of the optoelectronic transmission system
MOD21: Test of draw-in protection before door opening run (additional module
required)
MOD22: Test of external safety devices before door closing run (additional module
required)
MOD1 – MOD28
MOD1 – MOD28
MOD1 – MOD28
MOD1 – MOD28
MOD6
MOD7
MOD1
MOD14