22 – CS 300 RM Gate Controls / Rev. B 1.0
9. Overview of functions
9.3 Diagnosis operating mode
Display
Meaning
Status
UP-SWITCH
UP-SWITCH
ON:
activated
OFF:
not activated
SECT.-SWITCH
PART OPEN button (X4 / 9 + 10)
ON:
activated
OFF:
not activated
DOWN SWITCH
DOWN button
ON:
activated
OFF:
not activated
SKS
Safety edge protection
ON:
System is closed
OFF:
System is interrupted (fault)
IMPULS
Impulse button
ON:
activated
OFF:
not activated
SWITCH CLOCK
Weekly timer (switch clock)
ON:
activated
OFF:
not activated
LIGHT BARR
Drive-through light barrier
ON:
closed
OFF:
interrupted (fault)
STOP CHAIN
- Stop button of controls
- Stop systems of drive
ON:
closed
OFF:
interrupted (fault)
BES CLOSE
Pre-limit (before end) switch CLOSE
OFF:
actuated
ON:
not actuated
CYCLE
Door cycle counter
Display shows the number of door cycles