Installation and user 

manual

Evolution

S 1250 RT 2U

S 1750 RT 2U

   2000 RT 2U

S 2500 RT 2U

S 3000 RT 2U

S 3000 RT 3U

S EXB 1250/1750 RT 2U

S EXB 2500/3000 RT 2U

S EXB 2500/3000 RT 3U

Summary of Contents for Evolution 2000 RT 2U

Page 1: ... R R U P T I B L E P O W E R P R O V I D E R www mgeups com Installation and user manual Evolution S 1250 RT 2U S 1750 RT 2U 2000 RT 2U S 2500 RT 2U S 3000 RT 2U S 3000 RT 3U S EXB 1250 1750 RT 2U S EXB 2500 3000 RT 2U S EXB 2500 3000 RT 3U ...

Page 2: ...34008236EN AA Page 2 ...

Page 3: ...d electronic waste Battery The product contains lead acid batteries that must be processed according to applicable local regulations concerning batteries The battery may be removed to comply with regulations and in view of correct disposal The Material Safety Data Sheets MSDS for the batteries are available on our web site For more information or to contact the Product Environmental manager use th...

Page 4: ...ction Pictograms Important instructions that must always be followed Information advice help Visual indication Action Audio signal In the illustrations on the following pages the symbols below are used LED off LED on LED flashing ...

Page 5: ...ith a FlexPDU Power Distribution Unit module 11 2 6 Connections with a HotSwap MBP module 11 HotSwap MBP module operation 12 2 7 UPS connection without a FlexPDU or HotSwap MBP module 12 3 Operation 3 1 Start up and normal operation 13 3 2 Operation on battery power 13 3 3 Return of AC input power 14 3 4 UPS shutdown 14 3 5 UPS remote control functions 14 4 Personalisation using external software ...

Page 6: ...2U S 3000 RT 2U 440 x 86 x 634 S 3000 RT 3U 440 x 131 x 484 S EXB 1250 1750 RT 2U 440 x 86 x 509 S EXB 2500 3000 RT 2U 440 x 86 x 634 S EXB 2500 3000 RT 3U 440 x 131 x 484 Weights in kg S 1250 RT 2U 24 3 S 1750 RT 2U 26 6 2000 RT 2U 25 7 S 2500 RT 2U 33 8 S 3000 RT 2U 33 8 S 3000 RT 3U 34 3 S EXB 1250 1750 RT 2U 30 4 S EXB 2500 3000 RT 2U 41 5 S EXB 2500 3000 RT 3U 41 7 D H W ...

Page 7: ...ble outlets for connection of equipment 9 Groups of 4 outlets for connection of equipment 10 Socket for connection to AC power source Evolution S 1250 S 1750 2000 12 Connectors for battery modules to the UPS or to the other battery modules 13 Connectors for automatic recognition of battery modules 20 Bargraph indicating the percent load 21 Bargraph indicating battery charge level 22 Programmable o...

Page 8: ...ng on the version or optional 39 2 supports for the upright position RT 2U version only 40 FlexPDU module optional 41 connection cable between FlexPDU module and UPS 42 NMC communication card optional standard on Netpack versions 43 HotSwap MBP module optional 44 connection cables between HotSwap MBP module and UPS Packing materials must be disposed of in compliance with all local regulations conc...

Page 9: ...n It is advised to first install the battery module then the power module above Note The two supports for the upright position are used on the RT 2U version only Follow steps 1 to 4 for module mounting on the rails The rails and necessary hardware are supplied by MGE UPS SYSTEMS 1 1 2 3 3 2 4 2 4 1 1 1 1 ...

Page 10: ...UPS The UPS can now communicate with MGE UPS SYSTEMS power management software Limited access slot for the communication card It is not necessary to shutdown the UPS before installing a communication card 1 Remove the slot cover 4 secured by screws 2 Insert the communication card in the slot 3 Secure the card cover with the 2 screws Pins 1 3 4 5 6 10 not used Pin 2 common user Pin 7 low battery Pi...

Page 11: ...ection securing system that prevents the plugs from being pulled out accidentally 1 Connect the input socket 56 on the HotSwap MBP module to the AC power source using the cable 31 supplied 2 Connect the UPS input socket 10 to the UPS Input 55 on the HotSwap MBP module using the cable 44 supplied These cables and the connectors are marked blue 3 Evolution S 2500 S 3000 connect the UPS outlet 7 to t...

Page 12: ... 1750 2000 connect the UPS input socket 10 to the AC power source using the cable of the protected equipment Evolution S 2500 S 3000 connect the supplied cable 31 250 V 16 A to the socket 10 then to the AC power source 2 Connect the loads to the UPS using the cables 32 It is preferable to connect the priority loads to the four outlets marked 9 and the non priority loads to the four outlets marked ...

Page 13: ... are ON The load is supplied by the UPS on battery power The connected devices are protected by the UPS If LED 27 is ON a fault has occurred see the Troubleshooting section The connected devices continue to be supplied by the UPS when AC input power is no longer available The necessary energy is provided by the battery Button 24 and LEDs 25 and 26 are ON The audio alarm beeps every ten seconds The...

Page 14: ...intervention ROO Remote ON OFF allows remote action of button 24 to shut down the UPS These functions are obtained by opening a contact connected between the appropriate pins of connector 5 on the rear panel of the UPS see figures below Remote control connection and test All the LEDs go OFF The audio alarms stops The UPS is completely shut down Press button 24 for approximately 2 seconds The devic...

Page 15: ...S shutdown LED 26 goes ON To return to normal operation deactivate the remote external contact LED 26 goes OFF and restart the UPS by pressing button 24 4 Plug connector 5 into the back of the UPS 5 Connect and restart the UPS following the previously described procedures 6 Activate the external remote shutdown contact to test the function Warning This connector must only be connected to SELV Safe...

Page 16: ...ion Factory setting Other available settings High threshold for transfer to battery 294 Volts AC 271 to 294 Volts AC Low threshold for transfer to battery 160 Volts AC 160 to 180 Volts AC Fader activation threshold 265 Volts AC 244 to 265 Volts AC Booster activation threshold 184 Volts AC 184 to 207 Volts AC Maximum input voltage range Disabled Enabled 1 Function Factory setting Other available se...

Page 17: ...battery module see section 5 2 Battery module replacement 5 LED 27 alone is ON and the buzzer sounds continuously A UPS internal fault has occurred and the load is not supplied Call the after sales support department Indication Diagnostic Correction 6 The load is no longer supplied when the rotary switch 49 on the HotSwap MBP module is set to Bypass position The protected devices are connected to ...

Page 18: ...ove watches rings bracelets and all other metal objects from the hands and arms Use tools with an insulated handle Battery module removal A Unscrew the left hand side of the front panel two screws B Remove the part C Disconnect the battery block by separating the two connectors never pull on the wires D Remove the metal protection cover in front of the battery two screws E Pull the plastic tab to ...

Page 19: ...nected to the HotSwap MBP module 2 Start the UPS by pressing the ON OFF button 24 on the UPS control panel LED 51 UPS ON OK to switch on the HotSwap MBP module goes ON otherwise there is a connection error between the HotSwap MBP module and the UPS 3 Set switch 53 to Normal position The red LED on the HotSwap MBP module goes OFF To fully master operation of your MGE UPS SYSTEMS product and carry o...

Page 20: ...ing 20A 250V This product is designed for IT power distribution system Evolution S 1250 Evolution S 1750 Evolution 2000 Evolution S 2500 Evolution S 3000 Output power 1250VA 1150W 1750VA 1600W 2000VA 1600W 2500VA 2250W 3000VA 2700W AC input power Rated input voltage Input voltage range Input frequency range Single phase 220 240 V 160 V to 294 V 1 47 to 70 Hz 50 Hz system 56 5 to 70 Hz 60 Hz system...

Page 21: ... for installation in a bay There are different modules with different types of outlets HotSwap MBP UPS manual bypass module for maintenance There are different modules with different types of outlets Load Devices or equipment connected to the UPS output Low battery warning This is a battery voltage level indicating that battery power is low and that the user must take action in light of the immine...