background image

Quick Start

1

86-86000-03 B00

STEP 1   EX RT Transformer Module Unpacking and Parts Check

STEP 2   EX RT Transformer Module Tower Configuration

EX RT Transformer Module Quick Start

Warranty and 

Product Registration

EX RT Transformer

Quick Start Manual

EX  RT  Transformer Module Box Contents

Tower Stand Extenders

Stabilizer Bracket

(4 screws included)

41

Transformer 

Rail Kit

Transformer 

Cable

www . mgeops.com

EX 5/7/11RT Systems

Quick Start

Tower Configuration of Standard System with Transformer Module

 

Transformer Module

E X   1

1  R T

E X B  

 11  R T

Power Module

Battery 
Module
(up to 6)

Power Module

Battery Module

Transformer Module

5

1

1

2

2

4

4

4

4

3

3

Summary of Contents for EX 5RT

Page 1: ...s c o m EX RT Transformer Module Quick Start Standard Features When used with standard system EX RT Transformer Module provides isolated and Step down 120 208 240 Vac outputs Multiple Output receptacles 120 208 240 Vac ...

Page 2: ......

Page 3: ...er Quick Start Manual EX RT Transformer Module Box Contents Tower Stand Extenders Stabilizer Bracket 4 screws included 41 Transformer Rail Kit Transformer Cable w w w m g e o p s c o m EX 5 7 11RT Systems Quick Start Tower Configuration of Standard System with Transformer Module Transformer Module E X 11 R T E X B 11 R T Power Module Battery Module up to 6 Power Module Battery Module Transformer M...

Page 4: ...r 3 BATTERY MODULE lower EXB 5 7 11 RT 4 BATTERY MODULE bottom EXB 5 7 11 RT Shown with power module and 2 battery modules B Rack Installation 3 4 4 4 4 2 2 1 4 4 5 1 6 6 6 1 Attach both front mounting ear brackets to module with supplied screws For this step it is possible to adjust the position of both front mounting brackets 2 Attach rear support brackets to module These brackets prevent the mo...

Page 5: ...ac 240Vac Transformer Module Terminal block capacity maximum 4 AWG solid or stranded wire on transformer module 1 Check that the battery circuit breaker is OFF 0 position 2 Connect the battery power cable to the connectors of the power and battery modules 3 Connect the battery detection cable between connectors of the power and battery modules 4 Turn on battery module circuit breaker power module ...

Page 6: ......

Page 7: ......

Page 8: ...te 101 Irvine California 92618 www mgeops com w w w m g e o p s c o m Contact MGE Office Protection Systems United States MGE Office Protection Systems 13 Whatney Suite 101 Irvine CA 92618 949 268 2800 www mgeops com ...