background image

Pulsar EX7/EX10/EX15/EXB10/EXB15 presentation

présentation de Pulsar EX7/EX10/EX15/EXB10/EXB15

presentación de Pulsar EX7/EX10/EX15/EXB10/EXB15

general contents /  sommaire général / sumario general

Pulsar presentation

.............................................................................................................................

3

présentation de Pulsar
presentación de Pulsar

english

.......................................................................................................................................................................

11

getting started / operation

français

....................................................................................................................................................................

19

mise en service / exploitation

español

.....................................................................................................................................................................

27

puesta en servicio / explotación

Pulsar EX : 51032233XT/AC

MGE UPS SYSTEMS

1

2

Pulsar EX : 51032233XT/AC

MGE UPS SYSTEMS

Summary of Contents for Pulsar EX10

Page 1: ...Pulsar EX 51032233XT AC MGE UPS SYSTEMS Manuel d utilisation User Manual Manual de instrucciones PulsarTM EX7 EX10 EX15 EXB10 EXB15...

Page 2: ...meilleurs MGE UPS SYSTEMS Le agradecemos la compra del ondulador EX Lo invitamos a leer este manual esperando que ste le brindar todos los elementos necesarios para la instalaci n y la utilizaci n de...

Page 3: ...convey any permission to reproduce print or manufacture the article or articles shown herein Such permission may be granted only by specific written authorization signed by an officer of MGE UPS SYST...

Page 4: ...Pulsar EX 51032233XT AC MGE UPS SYSTEMS Postal address 1660 Scenic Avenue Costa Mesa CA 92626 714 557 1636 51032233XT AC MGE UPS SYSTEMS Inc...

Page 5: ...spose of battery or batteries in a fire The battery may explode c CAUTION do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes It may be toxic c CAUTIO...

Page 6: ...y supplying your sensitive equipment Pulsar EX7 EX10 and EX15 are designed as compact units and feature very silent operation They can be installed under a desk and can also be installed in a rack see...

Page 7: ...IBM Lan Server Artisoft LANtastic Banyan Vines Apple System 7 IBM AS400 and many others c UPS Manager 2 communication software this software can be used for automatic file closing on one or more serv...

Page 8: ...d recording of events in a log file v during long term power outages automatic shutdown of the system and of the UPS followed by automatic restart of the UPS system reboot on return of utility power v...

Page 9: ...XB10 EXB15 general contents sommaire g n ral sumario general Pulsar presentation 3 pr sentation de Pulsar presentaci n de Pulsar english 11 getting started operation fran ais 19 mise en service exploi...

Page 10: ...ew vue arri re vista trasera rear view vue arri re vista trasera 1a 1b 1f 2 3 1c 1d 1e T 15A 125V Vac IN U Talk 10 4 12 6a 6b 6 13 9 7 5 I max 8 3A Vac OUT Site wiring fault 8 11 18 16 solution pac 17...

Page 11: ...contents getting started 12 location 12 preliminary checks 12 connections 12 communication 13 operation 14 starting up with utility power present 14 starting up with out utility power 15 operation on...

Page 12: ...X use the supplied cord Note 4 if site wiring fault LED 8 is lit and buzzer sounds line neutral connections are reversed c connection of the Pulsar EXB10 EXB15 battery extension module optional v chec...

Page 13: ...wing pinouts 1 ground 4 normal operation 5 common 6 operation on utility power 7 low battery warning 8 load supplied by UPS 9 operation on battery optional port 12 5 4 3 2 1 9 8 7 6 0V 0V n o n c 0V n...

Page 14: ...s beep output off output off normal operation indicator lights test press button on off automatic sequence your load is supported by the battery 1a to 1f flashing device and battery test indicating t...

Page 15: ...tion on battery indicator lights test press on off button automatic sequence your load is supported by the battery 1a to 1f flashing UPS is on utility power device and battery test indicating the rema...

Page 16: ...vate the audio warning device when operating on battery or when site wiring fault occured If utility power is present hold alarm silence button in x mn x mn 5 mn 0 mn to if Pulsar is operating on batt...

Page 17: ...following occurs recharge your battery for 8 hours 1c flashing 1e off 1f on 1 beep every second operation on bypass see overload and device fault section Note This operating mode provides temporary i...

Page 18: ...18 Pulsar EX E 51032233XT AC MGE UPS SYSTEMS www kesintisizservis com...