background image

ii

Pulsar EX

Rack : 86-153522-00

MGE UPS SYSTEMS

introduction

In critical situations, count on MGE UPS
SYSTEMS Pulsar EX10

Rack and

EX15

Rack uninterruptible power supplies

(UPS). Their protection keeps your data
intact and accessible.
Pulsar EX10

Rack and EX15Rack UPSs

ensure top quality power around the clock,
and continue operations during power
failures. An intelligent microprocessor
detects any operating anomalies of the UPS
and triggers an alarm if corrective action is
necessary.
In addition to the high-technology aspect of
these UPSs, you can count on backup from
our staff, a team of specialists, around the
corner from you, throughout the world. It’s
no accident that MGE UPS SYSTEMS is the
world leader in UPS protection.

uses of Pulsar EX10

Rack and

EX15

Rack:

Network servers and interconnection
devices are very sensitive to electrical
disturbances of all types, including outages,
voltage sags, brownouts, spikes, etc. The
origins of the disturbances also vary, ranging
from atmospheric phenomena, to nearby
devices generating interference such as
elevators, photocopy machines and machine
tools, not to mention human errors, like the
accidental pulling out of power cords or
tripping of circuit breakers. The
consequences of these disturbances on
computer systems range from data losses to
hardware damage (power supplies, hard
disks).

Pulsar EX10

Rack and EX15Rack are

specially designed to protect network
servers and all other devices that are
sensitive to electrical disturbances.
Pulsar EX10

Rack and EX15Rack add fault-

tolerance to the utility supplying your
sensitive equipment.
Pulsar EX10

Rack and EX15Rack are

designed as compact units and feature very
quiet operation.
Pulsar EX10

Rack and EX15Rack provide a

stable supply of clean power, long back-up
time during a utility outage (see table) and
vast information and control possibilities
according to the configuration selected.
Pulsar EX10

Rack and EX15Rack On-Line

technology provides maximum protection
and availability of your workstations, servers,
and network communication devices.
Pulsar EX10

Rack and EX15Rack offer

many functions and characteristics designed
to simplify power management:

c

automatic battery test carried out

periodically. In the event of a fault, a LED
provides advance warning for battery
replacement;

c

front panel LEDs signal all types of faults

and alarms;

c

Bar graph continuously indicates the

battery charge level or the critical load power
level;

c

Pulsar EX10

Rack and EX15Rack are

environment friendly:  all components are
recyclable and an electronic power-saver
device reduces power consumption if the
UPS is not active for a period exceeding 5
minutes while on battery back-up;

c

EX Driver software provides rapid startup

of Pulsar EX10

Rack and EX15Rack using

the EX Tuner configuration module. This
module adapts Pulsar EX10

Rack and

EX15

Rack to user preferences (battery test

frequency, startup and shutdown
sequences, setting of battery thresholds,
etc.).  See "communication" section for
further details;

c

Solution-Pac

TM

 is a CD-ROM which

contains all the tools needed to supervise
your UPS.

c

Simply download the EX driver utility from

the CD and Solution-Pac.  The UPS must be
serialy connected to a Windows PC.

Summary of Contents for Pulsar EX10Rack

Page 1: ...Pulsar EXRack 86 153522 00 MGE UPS SYSTEMS User Manual PulsarTM EX10Rack EX15Rack EXB10Rack www mgeups com...

Page 2: ...ral Communications Commission FCC Statement Note this equipment has been tested and found to comply with Part 15 of the FCC Rules These limits are designed to provide reasonable protection against har...

Page 3: ...UTION do not dispose of battery or batteries in a fire The battery may explode c CAUTION do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes It may be...

Page 4: ...and EX15Rack add fault tolerance to the utility supplying your sensitive equipment Pulsar EX10Rack and EX15Rack are designed as compact units and feature very quiet operation Pulsar EX10Rack and EX15R...

Page 5: ...tion MGE has the most complete offering for the administration of a group of UPSs using the SNMP protocol with different network connection modules SNMP card or proxy software supervision modules appl...

Page 6: ...utomate system shutdown supervise and remotely control the UPSs MGE UPS SYSTEMS created Solution PacTM for this purpose Solution PacTM combines all these functions in a single CD ROM usable in local o...

Page 7: ...EX10Rack EX15Rack EXB10Rack EXB15 presentation general contents Pulsar presentation 3 getting started operation 11 Pulsar EXRack 86 153522 00 MGE UPS SYSTEMS 1 2 Pulsar EXRack 86 153522 00 MGE UPS SY...

Page 8: ...b 1c 1f 1e 1a 2 3 18 MGE UPS SYSTEMS ATTN CUSTOMER SUPPORT SERVICES 1660 SCENIC AVENUE COSTA MESA CA 92626 PLACE STAMP HERE 14 17 The indispensable companion sofware for your UPS L indispensable compl...

Page 9: ...flashing slowly indicate the battery charge level if utility power present or remaining battery time if no utility power present They may be on continuously or flash slowly during a transition period...

Page 10: ...V 7 2Ah note battery life 4 or 5 years is halved every 10 C above 25 C c output specifications v voltage V single phase 120V 3 can be adjusted from 100 to 127V using EX Driver v frequency F 50 60Hz 0...

Page 11: ...16 slots tower server modular hub tower server 100 lines PBX desktop server entry level mini computer system t h 0 1 2 3 EX10Rack 2 EXB10Rack EX10Rack EXB10Rack EX10Rack t min 0 80 160 240 320 EX15Ra...

Page 12: ...8 P ulsar EXRack 86 153522 00 MGE UPS SYSTEMS...

Page 13: ...contents getting started 10 location 10 preliminary checks 10 connections 10 communication 11 operation 12 starting up with utility power present 12 starting up with out utility power 13 operation on...

Page 14: ...se the supplied cord c connection of Pulsar EXB10Rack battery extension module optional v check that button 3 on the front of the Pulsar EX10Rack is not pushed in v disconnect the utility power connec...

Page 15: ...r communication port transmits the status information on a SUB D 9 pin female connector using the following pinouts 1 ground 4 normal operation 5 common 6 operation on utility power 7 low battery warn...

Page 16: ...UPS is on utility power 1 s beep output off output off normal operation indicator lights test press button on off automatic sequence your load is supported by the battery device and battery test indic...

Page 17: ...off output off normal operation on battery indicator lights test press on off button automatic sequence your load is supported by the battery UPS is on utility power device and battery test indicatin...

Page 18: ...n site wiring fault occured If utility power is present hold alarm silence button in x mn x mn 0 mn Pulsar switches off automatically warning alarm at low battery indicating the remaining battery time...

Page 19: ...recharge your battery for 8 hours operation on bypass see overload and device fault section Note This operating mode provides temporary inverter fault tolerance no utility power present Pulsar switche...

Page 20: ...16 Pulsar EXRack 86 153522 00 MGE UPS SYSTEMS...

Page 21: ...may be used herein are owned by their respective companies and are referred to in an editorial fashion only two years warranty policy c MGE UPS SYSTEMS Inc herein after referred to as MGE warrants Pu...

Page 22: ...Pulsar EXRack 86 153522 00 MGE UPS SYSTEMS Postal address 1660 Scenic Avenue Costa Mesa CA 92626 714 557 1636 86 153522 00 MGE UPS SYSTEMS Inc www mgeups com...

Reviews: