Pulsar EX : 51032278XT/AB

MGE UPS SYSTEMS

ENGLISH
introduction

In critical situations, count on MGE UPS
SYSTEMS Pulsar EX20 and EX30
uninterruptible power supplies (UPS). Their
protection keeps your data intact and
accessible.
Pulsar EX20 and EX30 UPSs ensure top
quality power around the clock, and continue
operations during power failures. An
intelligent microprocessor detects any
operating anomalies of the UPS and triggers
an alarm if corrective action is necessary.
In addition to the high-technology aspect of
these UPSs, you can count on backup from
our staff, a team of specialists, around the
corner from you, throughout the world. It’s
no accident that MGE UPS SYSTEMS is the
world leader in UPS protection. The UPS
shall provide power factor correction to
prevent harmonic distorsions and current
created by non-linear critical loads from
polluting the incoming AC line.

UPS includes:

c

batteries,

c

power factor correction / battery charger,

c

DC to DC converter,

c

DC to AC Converter,

c

bypass switch,

c

input/output filters.

The MGE Pulsar UPS is capable of
providing the following modes of operation:

c

ON LINE MODE which is the primary

mode of operation in which the critical load
is continuously supplied by the inverter and
protected from all forms of power line
disturbances:

ranging from atmospheric phenomena, to
nearby devices generating interference such
as elevators, photocopy machines and
machine tools, not to mention human errors,
like the accidental pulling out of power cords
or tripping of circuit breakers. The
consequences of these disturbances on
computer systems range from data losses to
hardware damage (power supplies, hard
disks).
Pulsar EX20 and EX30 are specially
designed to protect network servers and all
other interconnection devices that are
sensitive to electrical disturbances.
Pulsar EX20 and EX30 add fault-tolerance
to the utility supplying your sensitive
equipment.
Pulsar EX20 and EX30 are designed as
compact units and feature very quiet
operation. They can be installed under a
desk, and can also be installed in a rack
(see "options").
Pulsar EX20 and EX30 provide a stable
supply of clean power, long back-up time
during a utility outage (see table) and vast
information and control possibilities
according to the configuration selected.
Pulsar EX20 and EX30 On-Line technology
provides maximum protection and
availability of your workstations, server, and
network communication devices.
Pulsar EX20 and EX30 offer many functions
and characteristics designed to simplify
power management:

c

automatic battery test carried out

periodically. In the event of a fault, a LED
provides advance warning for battery
replacement;

c

BYPASS MODE which is a default mode

in the event of an inverter failure or overload
in which the critical load is supplied AC
through EMI/RFI filter:

application of Pulsar EX20 and
EX30:

Network servers and interconnection
devices are very sensitive to electrical
disturbances of all types, including outages,
voltage sags, brownouts, spikes, etc. The
origins of the disturbances also vary,

critical 

system

AC 

IN

EMI 

filter

power 

factor 

corrector 

rectifier

charger

DC / DC

micro 

control and 

DC to AC 

inverter

monitored 

batteries

critical 

system

AC 

IN

EMI 

filter

power 

factor 

corrector 

rectifier

charger

DC / DC

micro 

control and 

DC to AC 

inverter

monitored 

batteries

Summary of Contents for Pulsar EX20

Page 1: ...Manuel d utilisation User Manual Manual de instrucciones PulsarTM EX20 EX30 EXB20 30 Pulsar EX20...

Page 2: ...decemos la compra del SAI EX Lo invitamos a leer este manual esperando que ste le brindar todos los elementos necesarios para la instalaci n y la utilizaci n de su SAI EX Cont ctenos al siguiente n me...

Page 3: ...convey any permission to reproduce print or manufacture the article or articles shown herein Such permission may be granted only by specific written authorization signed by an officer of MGE UPS SYST...

Page 4: ...Postal address 1660 Scenic Avenue Costa Mesa CA 92626 714 557 1636 MGE UPS SYSTEMS Inc 51032278XT AB...

Page 5: ...ies in a fire The battery may explode c CAUTION do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes It may be toxic c CAUTION a battery can present a...

Page 6: ...urbances on computer systems range from data losses to hardware damage power supplies hard disks Pulsar EX20 and EX30 are specially designed to protect network servers and all other interconnection de...

Page 7: ...ur requirements c isolation transformer input line cord plugs into the Pulsar EX30 output receptacle Rating is 120V AC input 208V 240V AC 2 75 kVA output c maintenance bypass switch enables the user t...

Page 8: ...recording of events in a log file v during long term power outages automatic shutdown of the system and of the UPS followed by automatic restart of the UPS system reboot on return of utility power v P...

Page 9: ...general contents sommaire g n ral sumario general Pulsar presentation 3 pr sentation de Pulsar presentaci n de Pulsar english 11 getting started operation fran ais 19 mise en service exploitation esp...

Page 10: ...sta trasera CIRCUIT BREAKER 120Vdc 40A 19 23 Volt 96Vdc 20A Volt 96Vdc 20A 22 20 21 solution pac 17 CIRCUIT BREAKER 30A 125V T INPUT U TALK 10 12 13 5 I max 15A Vac OUT SITE WIRING FAULT 8 11 EXT BATT...

Page 11: ...contents getting started 12 location 12 preliminary checks 12 connections 12 communication 13 operation 14 starting up with utility power present 14 starting up with out utility power 15 operation on...

Page 12: ...onnect the input connection cord v flip the circuit breaker of the battery unit to the right position O v connect the battery connection cord to the DC connector of the battery module and connect to t...

Page 13: ...to COM4 set up by EX Tuner series port of your computer equipped with Windows 3 1 on the one end and to the serial Pulsar EX connector on the other end Insert the disk and type A Install Follow the i...

Page 14: ...s beep output off output off normal operation indicator lights test press button on off automatic sequence your load is supported by the battery 1a to 1f flashing device and battery test indicating t...

Page 15: ...tion on battery indicator lights test press on off button automatic sequence your load is supported by the battery 1a to 1f flashing UPS is on utility power device and battery test indicating the rema...

Page 16: ...ing on battery or when site wiring fault occured Note 2 The function button allows you to force a transfer on bypass push three times within 5 seconds and to come back on normal operation push again t...

Page 17: ...the following occurs recharge your battery for 8 hours 1c flashing 1e off 1f on 1 beep every second operation on bypass see overload and device fault section Note This operating mode provides temporar...

Page 18: ...18 Pulsar EX E 51032278XT AB MGE UPS SYSTEMS...