4.6.3 Calibrating the user defined pressure, temperature and current senders
1. Enter the number of points that you want to calibrate.
2. Enter the display reading that you want to show when the sender is at that actual
display reading.
3. Enter the ADC (analog to digital converter) reading that corresponds to this display
reading. The ADC reading is shown at the top of the display if you are applying the
actual stimulus from the temperature, pressure or current sender. You can also
manually enter this value if the ADC value is known or pre-calculated.
4. Continue entering display and ADC values until all the points have been entered.
5. Verify the above calibration by checking the temperature, pressure or current display
versus the actual applied sender stimulus.
4.6.4 Current Setup (requires a MGL Avionics Closed Loop Current Sensor)
Mode:
Select the function for the analog channel. Options are “PRESSURE”, “TEMP”, “CURRENT”, “FUEL LEVEL” or “OFF”.
Label:
Enter a label to suit your current channel so you can identify it easily.
Display Max:
Select the maximum current that you want the bargraph to show. This can give you increased display resolution.
Display Min:
Select the minimum current that you want the bargraph to show. This can give you increased display resolution.
High Alarm:
This enables or disables the current high alarm.
High Alarm:
Enter the current threshold for when the high alarm must be activated. Any current above this value will activate the
alarm.