Blaze EMS-2 Operating Manual
Page 40
4.12.2 Data payload
Message type=1
Data Length=69 bytes
Output Rate=1Hz
Unused channels will read 0
Local Time:
Unsigned Long (32 bit), Time is seconds since 1 January 1970
Hobbs Hours:
Unsigned Int (16 bits), Hobbs hours
Hobbs Minutes:
Unsigned char (8 bits), Hobbs decimal minutes
Maintenance Time:
Unsigned Int (16 bits), Maintenance time in hours
Volts:
Unsigned Int (16 bits), Volts in 0.1V
RPM 1:
Unsigned Long (32 bit), RPM 1 value
RPM 1 (%):
Unsigned Int (16 bit), RPM 1 value in percentage
RPM 2:
Unsigned Long (32 bit), RPM 2 value
RPM 2 (%):
Unsigned Int (16 bit), RPM 2 value in percentage
Analog Channel Type: Unsigned Int (16 bits)
CH4 (4 bits), CH3 (4 bits), CH2 (4 bits), CH1 (4 bits)
0=Off
1=Pressure
2=Temperature
3=Current
4=Fuel Level
Analog Channel 1:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
Current in 0.1A
Fuel Level in Liters
Analog Channel 2:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
Current in 0.1A
Fuel Level in Liters
Analog Channel 3:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
Current in 0.1A
Fuel Level in Liters
Analog Channel 4:
Signed Int (16 bits)
Pressure in 0.1psi